Bias
Consumption
Current
Adjustment
Note
:
The
bias
consumption
current
must
be
adjusted
before
adjusting
the
record
bias.
Retry
record
bias
adjustment
after
the
bias
consumption
current
is
adjusted.
Procedure
:
1.
Set
semi-fixed
resistors
RV104
(L-CH),
RV204
(R-CH)
and
RV505
for
record
bias
adjustment
to
mechanical
center,
and
select
the
recording
mode
without
applying
a
signal.
2.
Adjust
T101
(L-CH)
and
T201
(R-CH)
so
that
the
digital
voltmeter
reading
becomes
minimum.
Digital
voltmeter
B+
(+8.5V)
Adjustment
Value
:
120mV
or
less
(This
Value
is
measured
using
CS-413
after
bias
adjustment.)
Bias
and
Recording
level
adjustment
Condition
:
REC
LEVEL
control
:
Specified
recording
position
(page
10)
Procedure
:
1.
Mode
:
simultaneous
record
and
playback
LINE
IN
AF
OSC
315Hz,
50mV
(—23.8dB)
10kHz,
50mV
(-23.8dB)
oo
"3
10kQ
O|
Attenuator
o-oo
11
OOO
_
Crete
Oscilloscope
VTVM
J
ed)
ee
oO
|
|
LINE
OUT
2.
Adjust
the
following
controls
so
that
the
minimum
output
becomes
the
specified
output
level.
(1)
RV104
(L-CH)
and
RV204
(R-CH)
......
Bias
adjustment
(2)
RV103
(L-CH)
and
RV203
(R-CH)
......
Recording
level
adjustment
Adjustment
Value
:
(1)
Level
of
10kHz
against
315Hz
:
0
+
0.3dB
(2)
315Hz
level
:
48.3
to
51mV
(—24.1
to
—23.5dB)
Metal
Bias
Adjustment
Condition
:
REC
LEVEL
control
:
Specified
recording
position
(page
10)
Procedure
:
1.
Mode
:
simultaneous
record
and
playback
315Hz,
50mV
(—23.8dB)
AF
OSC
10kHz,
50mV
(-23.8dB)
Blank
tape
*
10kQ
LINE
IN
CS-413
O
Attenuator
|
Ree
|
't
OOO”
6
Gy
OM
LINE
OUT
2.
Adjust
RV505
so
that
10kHz
R-CH
output
is
+
0.3dB
relative
to
the
315Hz
output.
Calibration
Adjustment
Condition
:
CALIBRATION
switch
:
ON
TP801
:
The
state
of
short-circuit
Adjustment
method
(Oscillation
input
level)
:
1.
Short-circuit
the
test
point
TP801
of
system
control
(A)
board.
2.
Adjust
RV904
(HIGH),
RV905
(MID)
and
RV906
(LEVEL)
to
become
the
level
meter
as
the
following
display.
a
HIGH
Vv
SRS
MID
LEVEL
>ma<
3.
As
for
HIGH
and
MID,
the
segment
with
AV
mark
in
the
left
side
should
be
lit.
(approve
of
flashing)
And
when
the
left
segment
is
flashing,
the
right
segment
is
approved
of
flashing.
4.
As
for
LEVEL,
@
mark
should
be
lit.
(Both
ends
are
approved
of
flashing.)
5.
Release
the
short-circuit
of
TP801.