SECTION
3
ADJUSTMENTS
3-1.
MECHANICAL
ADJUSTMENTS
PRECAUTION
1.
Clean
the
following
parts
with
a
denatured
alcohol-moistened
swab:
record/playback/erase
head
rubber
belts
idlers
2.
Demagnetize
the
record/playback
head
with
a
head
demagnetizer.
(Head
demagnetizer
do
not
approach
for
the
erase
head.)
3.
Do
not
use
a
magnetized
screwdriver
for
the
adjustment.
4.
After
the
adjustments,
apply
suitable
locking
compound
to
the
parts
adjusted.
5.The
adjustments
should
be
performed
with
the
rated
power
supply
voltage
unless
otherwise
noted.
pinch
roller
capstan
Torque
Measurement
Meter
reading
CO-102C
28
to
60g
*
cm
(0.39
to
0.830z
*
inch)
oS
3-2.
ELECTRICAL
ADJUSTMENTS
Forward
2
to
6g
*cm
(0.028
to
0.083
oz
*
inch)
PRECAUTION
1.
The
adjustment
should
be
performed
in
the
publication.
(Be
sure
to
male
playback
adjustment
at
first.)
2.
The
adjustments
and
measurement
should
be
performed
for
both
L-CH
and
R-CH.
@
Switch
position
DOLBY
NR
switch
SOrE
DIRECTION
switch
=
@
Standard
record
position
:
Deliver
the
standard
input
signal
level
to
input
jack
and
set
the
REC
LEVEL
control
to
obtain
the
standard
output
signal
level
as
follows.
Record
Mode
AF
OSC
VTVM
q)
attenuator
10k
Q
oO
O
I]
ooo
ae
LINE
OUT
LINE
IN
Standard
Input
Level
Standard
Output
Level
Test
Tape
10kHz,
10dB
Azimuth
Adjustment
315Hz,
0dB
PB
Level
Adjustment
3kHz,
0dB
Tape
Speed
Adjustment
OdB=0.775V
Test
Mode
1.
Insert
a
short-circuit
plug
into
TP801
(2P)
and
turn
ON
the
power
switch.
(Earth
pin
@
of
IC801
and
turn
ON
the
power
switch.)
At
first,
all
the
fluorescent
tubes
light
up,
then
the
system
returns
to
normal
display.
2.
To
release
the
test
mode,
remove
the
short
plug
and
tum
off
the
power
switch.
3.
Remove
the
short
plug
after
completion
of
adjustment.
Record/Playback
Head
Azimuth
Adjustment
Procedure
:
1.
Forward
playback
Mode
test
tape
P-4-A100
(10kHz,
10dB)
VTVM
LINE
OUT
2.Tum
the
adjustment
screw
for
the
maximum
output
levels.
If
these
levels
do
not
match,
turn
the
adjustment
screw
until
both
of
output
levels
match
together
within
1dB.
L-CH
within
peak
within
1dB
R-CH
peak
Pee
—r
screw
position
position
L-CH
R-CH
peak peak