16
XVM-R70
5-11. V COM VOLTAGE/POSITION ADJUSTMENT
Condition: TEST MODE (See 13 page)
1. Voltage Setup Adjustment
Adjustment method:
1) Select V Com from the FOR FACTORY MODE.
2) Connect oscilloscope between TP809 (+) and TP600 (–).
3) Adjust so that the p-p value A of the waveform stands at the
specified value using the
R
and
r
keys on the remote controller.
4) Adjust so that the level B on the negative side stands at the speci-
fied value using RV801.
5) Verify that the level C on the positive side stands at the specified
value.
Specified value A: 5.6 ± 0.1 Vp-p
Specified value B: –1.1 ± 0.1 V
Specified value C: 4.5 ± 0.1 V
Adjusting location: LCD board
5-12. VIDEO ADJUSTMENT
Conditions: TEST MODE (See 13 page)
10-step gray scale signal input
NTSC mode
5-12-1. Brightness Signal Contrast Level (Y GAIN)
Adjustment Method:
1) Select Y Gain from the FOR FACTORY MODE.
2) Connect oscilloscope between TP811 (+) and TP500 (–).
3) Adjust so that the signal level A stands at the specified value
using the
R
and
r
keys on the remote controller.
Specified value: 3.4 ± 0.1 V
Adjustment location: LCD board
5-12-2. Black Limiter Level Adjustment
Adjustment Method:
1) Select Black Limit from the FOR FACTORY MODE.
2) Connect oscilloscope between TP811 (+) and TP500 (–).
3) Adjust so that the signal level B stands at the specified value
using the
R
and
r
keys on the remote controller.
Specified value: 0.65 ± 0.01 V
Adjustment location: LCD board
5-12-3. White Limiter Level Adjustment
Adjustment Method:
1) Select White Limit from the FOR FACTORY MODE.
2) Connect oscilloscope between TP811 (+) and TP500 (–).
3) Adjust so that the signal level C stands at the specified value
using the
R
and
r
keys on the remote controller.
Specified value: 3.85 ± 0.05 V
Adjustment location: LCD board
5-12-4. R Sub Brightness Adjustment
Adjustment Method:
1) Select R SUS BRT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP812 (+) and TP500 (–).
3) Adjust so that the signal level D stands at the specified value
using the
R
and
r
keys on the remote controller.
Specified value: 1.1 ± 0.1 V
Adjustment location: LCD board
5-12-5. B Sub Brightness Adjustment
Adjustment Method:
1) Select B SUS BRT from the FOR FACTORY MODE.
2) Connect oscilloscope between TP810 (+) and TP500 (–).
3) Adjust so that the signal level E stands at the specified value
using the
R
and
r
keys on the remote controller.
Specified value: 1.1 ± 0.1 V
Adjustment location: LCD board
A
0V
B
0V
C
0V
D
0V
E
0V