This command identifies the data to be printed in the first column of the report. It allows
for a maximum of 14 characters in length. If less than 14 characters are sent, the printer
fills the field with spaces when the audit report is printed. This field is only recorded in
the audit report; it is not printed on the check.
Audit Report Field Two-MICR Line &%SMDd..d$ or &%SM7d..d$
&%SMD or &%SM7 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the second column of the report. It
allows for a maximum of 40 characters in length.
Audit Report Field Three &%SQ3d..d$
&%SQ3 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the third column of the report. It allows
for a maximum of 40 characters.
Audit Report Field Four &%SQ4d..d~
&%SQ4 Lead in sequence
d..d Data to be printed
~ Command terminator
This command identifies the data to be printed in the fourth column of the report. It
allows for a maximum of 16 characters in length. Since a total of this field can be
provided at the end of the Audit Trail Report it is typically used for the convenience
amount field.
Note: This is the only command where the $ is not a command terminator. The
tilde ~ (hex 7E) acts as the command terminator.
Audit Report Field Five &%SQ5d..d$
&%SQ5 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the fifth column of the report. This field
allows for a maximum of eight characters.
Audit Report Field Six &%SQ6d..d$
&%SQ6 Lead in string
Audit Trail Reports | 7
Source Technologies, LLC ST9720 Secure MICR Printer User’s Guide