EasyManua.ls Logo

Southwire 11060S - Specifications; DC Voltage Specifications; AC Voltage Specifications; DC Current Specifications

Southwire 11060S
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Specifications
NOTE: Accuracy is stated at 65°F to 83°F (18°C to 28°C) and less than 70% RH.
Input Impedance: 10MΩ. Maximum Input: 1000V DC or 1000V AC rms.
Function Range Resolution Accuracy (% of reading)
DC Voltage
(Auto-ranging)
400.0mV
4.000V
40.00V
400.0V
1000V
0.1mV
1mV
10mV
100mV
1V
± 0.5% of rdg ± 3 digits
± 1% of rdg ± 3 digits
Input Impedance: 10MΩ.
AC Response: 50Hz to 400Hz
Maximum Input: 1000V DC or 1000V AC rms.
AC Voltage
(Auto-ranging)
400.0mV
4.000V
40.00V
400.0V
1000V
0.1mV
1mV
10mV
100mV
1V
± 1.0% of rdg ± 30 digits
± 1.2% of rdg ± 5 digits
Overload Protection: FF500mA / 1000V and F10A / 1000V Fuse
AC Response: 50Hz to 400Hz
Maximum Input: 4000uA AC rms. on uA, 400mA AC rms. on mA, 10A AC rms. on 10A range
AC Current
(Auto-ranging)
400.0uA
4000uA
40.00mA
400.0mA
10A
0.1uA
1uA
10uA
100uA
10mA
± 1.2% of rdg ± 5 digits
± 2.5% of rdg ± 5 digits
Overload Protection: FF500mA / 1000V and F10A / 1000V Fuse
DC Current
(Auto-ranging)
400.0uA
4000uA
40.00mA
400.0mA
10A
0.1uA
1uA
10uA
100uA
10mA
± 1.0% of rdg ± 5 digits
± 2.5% of rdg ± 3 digits
Maximum Input: 4000uA DC on uA range, 400mA DC on mA range, 10A DC on 10A range
14
Specifications
Input Protection: 1000V DC or 1000V AC rms.
Function Range Resolution Accuracy (% of reading)
Resistance Ω
(Auto-ranging)
400.0Ω
4.000kΩ
40.00kΩ
400.0kΩ
4.000MΩ
40.00MΩ
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
± 0.8% of rdg ± 5 digits
± 0.8% of rdg ± 2 digits
± 2.5% of rdg ± 8digits
Sensitivity: >3V RMS while 1MHz ;
Sensitivity: >8V RMS while >1MHz ;
Input Protection: 1000V DC or 1000V AC rms.
Frequency
(Auto-ranging)
4.000Hz
40.00Hz
400.0Hz
4.000KHz
40.00kHz
400.0kHz
5.00MHz
0.001Hz
0.01Hz
0.1Hz
1 Hz
10Hz
100Hz
1kHz
± 1.0% of rdg ± 3 dgts
± 1.2% of rdg ± 4 dgts
Input Protection: 1000V DC or 1000V AC rms.
Capacitance
(Auto-ranging)
40.00nF
400.0nF
4.000uF
40.00uF
100.0uF
10pF
0.1nF
1nF
10nF
0.1uF
± 5.0% of rdg ± 7 dgts
± 3.0% of rdg ± 5 dgts
± 5.0% of rdg ± 7 dgts
IPulse width: >100us, <100ms;
Frequency width: 5Hz – 150kHz
Sensitivity: >8V RMS
Overload protection: 1000V DC or AC rms.
Duty Cycle
0.1%~99.9% 0.1%
± 1.2% of rdg ± 2 dgts

Related product manuals