The machine will auto-home first, then the entire X-axis will rise to the top for calibration, then descend to auto-home.
After clicking on Level
Bed, the nozzle will rise
to 120℃, and the hot
bed will rise to 60℃,
please be patient and
be careful of burns.
4
then click the level bed, the machine starts
to detect at 25 points on the hot bed.
1 2 3
4 5
11
7
89
12
10
14
13
6
17 16
1820 19
21 22
15
23
2
Click the Bed Leveling→Auto
Home(Preheat)→Auto Home
About 0.2mm, the thickness of a sheet of A4 paper,when you drag the
paper, the nozzle can scratch the paper slightly, that means the distance is suitable.
-
+
-
0.2mm
After adjusting, don't forget to click to store the settings.
After clicking Auto home for the
first time, the machine will be
preheated automatically: nozzle
120°C, hotbed 60°C. After the
temperature is reached, click
Auto Home again to process.
3
After the machine stops, go back and click Probe Z offset
to adjust the distance between the nozzle and the hot bed
After adjusting, don't
forget to click to store
the settings.
5.2 Leveling-2
5.3 Leveling-3
a
c
b