1.4
Specifications
FM 104/184
Operating
Temperature 32°F to 100°F (higher temperature construction is available).
Storage Temperature -40°F to 175°F
Materials of
Construction Coverplate .............................................................................. Cast Iron (2" - 14")
Coverplate .................................................................................. Steel (16" - 72")
Propeller ......................................................................................... Polyethylene
Gearbox ................................................................................... Bronze (2" - 30")
Gearbox ............................................................................... Cast Iron (36" - 72")
Mechanical Parts ........................................................................... Stainless Steel
Saddles ................................................................................ Cast Steel (6" - 14")
Saddles ..................................................................... Fabricated Steel (16" - 72")
Meter Tubes / Coatings ........ Cast Iron / stainless steel metering section (2" - 3")
Fabricated Steel (4" - 36")
Wetted parts high build epoxy polyamide paint EPA approved for potable water
FT 194-II
Accuracy Rate: ±0.25% of full scale
Totalization: ±0.1% of rate (in addition to propeller meter accuracy)
Power 3.6V Lithium battery (3 year average life)
4-20mA and scaled pulse output with external 24 Vdc power source
Battery operating temperature: -55°F to 185°F
Operating Temperature -10°F to 158°F (-23°C to 70°C)
Storage Temperature -40°F to 158°F (-40°C to 70°C)
Display 5-digit rate indicator (0.35 inches high)
8-digit totalizer indicator (0.25 inches high)
LCD display with simultaneous rate and total, and low battery indication.
Construction Sturdy die cast aluminum bonnet
NEMA-4X, NEMA-6, & IP67 environmental ratings.
Optional Outputs 4-20mA, scaled pulse output (open collector output, 100mA at 30 Vdc).
User selectable units of measure for every contact closure.
Scaling Totalizer Scaler: .001 to 999999
Scaling Units Totalizer - Gallons, cubic feet, liters, cubic meters, acre feet
Rate - GPM, CFS, MGD, LPS, M
3
/Hr
Electrical Rating General Purpose
Page 2 MainLine
TM
Power Supply vs. Output Load

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SPARLING MainLine FM-104 and is the answer not in the manual?

SPARLING MainLine FM-104 Specifications

General IconGeneral
BrandSPARLING
ModelMainLine FM-104
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals