16 ENGLISH
Fault table TC-2000
Warning: The unit should be de-energised immediately in the event of a malfunction. Repairs
should only be entrusted to trained and qualified skilled personnel.
Malfunctions Possible causes Remedy
The compressor motor NOTE: The auto-stop feature of Once pressure drops to 40
does not start this unit’s pressure switch psi/2.8 bar, the auto-start
automatically stops when the feature automatically restart
pressure reaches 60 psi/ the compressor’s motor
4.1 bar. This is not a fault
condition and is part of the
normal and expected behavior
of the unit.
No power Check to make sure the unit is
plugged in and the on/off switch
is in the ’’on“ position
Damaged electrical cables or Specialist workshop
loose electrical connections
Compressor running, Moisture trap not closed Pull down on the moisture trap
but does not build up knob
adequate pressure
Unused air outlet not covered Tightly secure covering cap on
unused air outlet
Leak in air hose or a poor Check all connections and air
connection hoses for potential leaks
Compressor does not start Defective pressure switch Have pressure switch replaced
when pressure is below by specialist workshop
auto-on pressure or
compressor does not stop when
auto-stop pressure reached
Warning: If pressure switch is defective, do not operate compressor above 80 psi/5.5 bar
Compressor becomes too hot Room temperature too high Ensure adequate room tempe-
or ventilation is inadequate rature and appropriate ventilation
Compressor overloaded Check whether compressor is
suitable for load
Compressor becomes too hot Thermal protector has shut Turn off the compressor and
and deactivates during down compressor allow unit to cool for at least
operation 30 minutes.
Note: No claim is made to the completeness of the possible malfunctions listed here.