INSTRUCTIONS FOR MODELS
92-SC-12XX-01
For additional assistance or service please contact:
SPEAKMAN
®
Company
400 Anchor Mill Road
New Castle, DE 19720
800-537-2107
customerservice@speakman.com
www.speakman.com
SC-1210 SERIES SC-1220 SERIES
SC-1230 SERIES
SC-1240 SERIES
HELPFUL TOOLS & SUPPLIES:
Pencil
TOOLS AND SUPPLIES
Thread Seal
Tape
Pipe
Wrench
Drill Drill Bit
3/16”
Mounting Hardware
(Included)
Adjustable
Wrench
Phillips
Screwdriver
Warranty information can be found at:
www.speakman.com
WARRANTY
MAINTENANCE
Cover your drain to prevent loss of parts. Be sure to
wear eye protection while cutting pipe.
SAFETY TIPS
FREEZE PROTECTION
Freeze damage to the shower unit will void the Freeze damage to the shower unit will void the
warranty. It is important to winterize the complete warranty. It is important to winterize the complete
shower unit. The unit must be drained of all water shower unit. The unit must be drained of all water
in freezing conditions. This includes removing the in freezing conditions. This includes removing the
valve cartridge and the shower head from the unit. valve cartridge and the shower head from the unit.
Store the valve cartridge and shower head indoors.Store the valve cartridge and shower head indoors.
• Mounting location must be capable of supporting
the product in use.
The shower valves are washerless and require no routine
maintenance. The gleaming finish of your SPEAKMAN
Commander shower can be cleaned by using mild soap
and warm water. Dry immediately with a soft, clean
cloth for best results. To remove the index button on the
vandal resistant handles, locate knockout hole on handle
underneath one of the arms of the handle. Insert a rigid
pin (1/8” diameter or smaller) into hole and knockout
index button.
Your new Speakman Product is designed for years of
trouble-free performance. Keep it looking new by
cleaning it periodically with a soft cloth. The use of harsh
chemicals and abrasives on any of the Speakman custom
finish products may damage the finish and void the
product warranty. Please be sure to only use approved
cleaners. Please contact Speakman for any clarification
of acceptable cleaners.
CAUTION: When outdoor temperature
rises above 90 degrees, use caution to
prevent scalding from water stored within
the unit. It is recommended to flush the unit
by turning it on for 30 seconds before
entering the shower water. This will avoid
accidental scalding by the user and ensure
safe use of the shower unit.
IMPORTANT
• Be sure to read instructions thoroughly before
beginning installation.
• Do not over-tighten any connections or damage
may occur.
• This shower valve has an operating range of
20-80 psi.
NOTE: Shut off water supplies. Supplies
must be on 6” centers. Recommended
height from center of valve body to floor
is 54”. Valve body is reversible to take
supplies from below.
1
Slide the Strap (1) onto the Shower Arm. Then
apply sealant to inlet threads of Shower Arm
and the Plug (3). Screw the Shower Arm into the
Valve Body (2). Tighten and position outlet
perpendicular with Valve Body. Use Adjustable
Wrench to tighten the Plug (3) into the Valve
Body (2).
2
Following the rough-in dimensions for your model (located ot the end of this manual), install Supply Pipes at
proper location. See images below for reference.
FITTING WITH WALL FLANGE:
Apply pipe sealant to one end of Supply Pipes
(provided). Screw pipes into supply lines.
NOTE- Supply lines must have 1/2 NPT female
threaded ends and be 1-1/8” from center of
supply line to finished wall.
FITTING WITH LUGS:
Supply lines must have 1/2 NPT male threaded
ends and be 7/8” from center of supply line to
finished wall.
18
1
2
"
470mm
5
1
2
"
143mm
4'-6'
137 Meters
TO FLOOR
8
7
16
"
215mm
6
3
16
"
157mm
SUPPLY LINE
FINISHED
WALL
SURFACE
1¹⁄8
MOUNTING DEPTH
FITTING WITH WALL FLANGE
4"-6"
[1.37 Meters]
TO FLOOR
18
1
2
"
470mm
5
1
2
"
143mm
7
1
4
"
193mm
FINISHED
WALL
SURFACE
7
8
MOUNTING DEPTH
FITTING WITH LUGS
3
Apply sealant to threads of Supply Lines (1). Slip
Coupling Nuts (2) onto Supply Lines and screw
Swivels (3) up hand tight. Gripping on small
diameter of Swivels with a Pipe Wrench, tighten
pipes and/or Swivels.
Question and Answer IconNeed help?

Do you have a question about the Speakman SC-1220 SERIES and is the answer not in the manual?

Summary

Shower Model Installation and Safety

Safety Guidelines and Precautions

Essential safety information for installation and operation, including freeze protection and warnings.

Support, Maintenance, and Warranty Information

Contact details, maintenance procedures, and warranty information for the shower unit.

Tools and Supplies for Installation

Lists all required and helpful tools and supplies for the installation process.

Installation Step 1: Shower Arm and Valve Connection

Guides the user through connecting the shower arm to the valve body and securing components.

Installation Step 2: Supply Pipe Placement

Details the installation of supply pipes according to rough-in dimensions for different fitting types.

Installation Step 3: Connecting Supply Lines

Explains how to connect the supply lines to the valve assembly using coupling nuts.

Mounting and Final Assembly Steps

Installation Step 4: Valve Body to Swivels

Connects the valve body to the supply lines using rubber washers and coupling nuts.

Mounting Assembly with Flange

Instructions for mounting the valve assembly to the wall using a flange.

Mounting Assembly with Lugs

Instructions for mounting the valve assembly to the wall using lugs.

Installation Step 7: Water Supply and Flush

Turns on water supplies and flushes both hot and cold sides of the fitting.

Final Connections and Repair Parts

Installation Step 8: Shower Arm and Head Connection

Attaching the shower head to the shower arm and checking for leaks.

Installation Step 9: Handle Operation

Guidance on operating the shower handles for the exposed shower.

Repair Parts for SC-1210, SC-1220, SC-1230, SC-1240

Lists part numbers and descriptions for common repair components.

Rough-in Diagram for SC-1210-AF

Provides dimensions and connection details for SC-1210-AF model rough-in.

Rough-in Diagram for SC-1220-AF

Provides dimensions and connection details for SC-1220-AF model rough-in.

Model Rough-in Diagrams

Rough-in Diagram for SC-1230-LH

Provides dimensions and connection details for SC-1230-LH model rough-in.

Rough-in Diagram for SC-1240-LH

Provides dimensions and connection details for SC-1240-LH model rough-in.

Speakman SC-1220 SERIES Specifications

General IconGeneral
BrandSpeakman
ModelSC-1220 SERIES
CategoryBathroom Fixtures
LanguageEnglish

Related product manuals