Operating Instructions
VU / VH Series
VU 20 - 1600
VH 20 - 1600
Liquid Ring Vacuum Pumps
English translation of the original operating
instructions
Documentation
It is imperative to read the operating instruc-
tions prior to commissioning!
This document as well as all documents in-
cluded in the appendix is not subject to any
update service!
Subject to technical changes.
Speck Pumpen Vakuumtechnik GmbH
Regensburger Ring 6 – 8, 91154 Roth / Germany
PO Box 1453, 91142 Roth / Germany
Phone: +49 (0) 9171 809 0
Fax: +49 (0) 9171 809 10
E-mail: info@speck-pumps.de
Internet: www.speck-pumps.de
Issue:
10/2010
Supersedes issue:
06/2010
Doc./ Item no.:
1096.0799

Table of Contents

Questions and Answers

  • J
    John AliAug 16, 2025
    What to do if my Speck pumpen VH 500 Water Pump motor protection is triggered?
    • D
      Dylan LawsonAug 16, 2025
      If the motor protection of your Speck pumpen Water Pump is triggered, it could be due to several reasons: * There may be a short-circuit in the motor winding. Check the motor winding. * The motor protection switch might not be correctly set or is defective. Check the setting or replace the switch. * The motor may be overloaded. Check and reduce the operating liquid flow rate. * There could be excessive backpressure in the outlet nozzle. Reduce backpressure. * There might be an excessive share of liquid in the suction flow. Reduce the share of liquid. * The suction-side fitting may be blocked. Open the suction-side fitting.
  • L
    Lawrence SmithAug 20, 2025
    Why is my Speck pumpen VH 500 motor consuming excessive power?
    • C
      Carmen WilliamsAug 20, 2025
      Excessive power consumption in your Speck pumpen Water Pump motor can occur due to: * Motor overload: Check and reduce the operating liquid flow rate. * Excessive backpressure: Reduce backpressure in the outlet nozzle. * Excessive share of liquid: Reduce the share of liquid in the suction flow. * Blocked suction-side fitting: Open the suction-side fitting. * High density/viscosity: Use an operating liquid complying with the density recommended in the data sheet. * Impeller rubbing: Disassemble the pump and properly set the inter casing/impeller gap size. * Pump contamination/calcification: Flush, descale, or disassemble the pump and clean it.
  • A
    Alexandra DavidsonAug 23, 2025
    What to do if my Speck pumpen VH 500 Water Pump is leaking?
    • G
      Garrett DavisAug 23, 2025
      If your Speck pumpen Water Pump is leaking, consider the following potential causes: * A defective shaft sealing. Replace the shaft sealing. * A defective casing sealing. Provide the vacuum pump with new sealing. * Worn-out casing components. Replace the affected components. * Loosened connecting screws or screw plugs. Tighten the screws and replace the sealing.
  • M
    Mary FreemanAug 27, 2025
    Why is my Speck pumpen VH 500 not producing vacuum?
    • J
      Justin GarciaAug 27, 2025
      If your Speck pumpen Water Pump is not producing vacuum, it could be due to: * A lack of operating liquid. Check the operating liquid supply. * A leak in the suction pipe. Check and seal the suction pipe and connections. * The wrong direction of motor rotation. Check the direction of rotation and swap the 2 phases if necessary.
  • A
    Ashlee HudsonAug 31, 2025
    Why is my Speck pumpen Water Pump not running smoothly?
    • J
      joshuahernandezAug 31, 2025
      If your Speck pumpen Water Pump isn't running smoothly, here are some possible causes: * Excessive operating liquid flow rate: Reduce the operating liquid flow rate. * Overload in the pipe system: Check the pipe connections, pump fixation, and bearing clearance of the pipe clamps. * Air pocket in the pipe: Change the pipe system layout. * Pump distorted/improperly adjusted: Check and re-adjust the pump. * Resonance vibrations in the pipe system: Check the pipe connections and, if required, use a compensator. * Imbalanced impeller: Balance or replace the impeller. * Deposits on the impeller: Clean or replace the impeller. * Defective pump or motor bearing: Replace the pump or motor bearing.
  • L
    Lauren MccoySep 7, 2025
    Why is my Speck pumpen VH 500 making a strange noise?
    • M
      Marie MaySep 7, 2025
      Strange noises from your Speck pumpen Water Pump can result from: * Pump cavitation: Install an anti-cavitation valve or equip the suction pipe with a ventilation valve. * Excessive steam: Reduce the share of steam or provide for condensation upstream the vacuum pump. * Suction-side fitting closed: Open the suction-side fitting or provide for cavitation protection. * Excessive operating liquid flow rate: Reduce operating liquid flow rate.
  • N
    Natalie PhillipsNov 11, 2025
    Why is my Speck pumpen VH 500 Water Pump motor not starting?
    • M
      Megan FordNov 11, 2025
      There are several reasons why the motor of your Speck pumpen Water Pump may not be starting: * A phase of the power supply could be interrupted. Check the power supply and the motor. * The motor protection switch may have tripped. Try switching it on. * The motor might be blocked. Inspect the motor. * There might be corrosion inside impeller/inter casing. Use rust remover to overcome the blockage of the pump. * Ice could be inside the pump. Carefully heat up and defrost the pump. * Contaminations or foreign bodies may be present inside the pump. Flush or disassemble the pump and clean it. * The pump may have calcified. Descale the pump. * The impeller could be blocked or defective. Correct the gap size of the inter casing/impeller or replace it. * The motor bearing may b...

Summary

Important Basic Information

Target Groups and Tasks

Identifies the intended users and their responsibilities within the manual.

Applicable Documents

Lists related documents essential for proper operation and compliance.

Warnings and Symbols

Explains safety signs and their associated risks and consequences.

Terminology

Defines key terms used throughout the operating instructions.

Safety

Intended Use

Specifies the correct and authorized applications for the pump/aggregate.

Possible Misuse

Outlines incorrect applications and potential hazards.

General Safety Instructions

Provides essential safety guidelines for operation and maintenance.

Residual Risks

Details inherent risks that remain even after safety measures are applied.

Special Risks

Highlights specific hazards related to explosive areas or dangerous media.

Design and Functioning

Marking

Explains labels and plates on the pump, including nameplate and ATEX.

General Description

Provides an overview of the pump series and its basic components.

Design and Functional Principle

Details how the liquid ring vacuum pump operates.

Shaft Sealing

Describes the types and function of shaft sealing mechanisms used.

Transport, Storage, and Disposal

Transport Procedures

Covers safe methods for unpacking, manual transport, and lifting.

Storage Guidelines

Provides instructions for proper storage to prevent damage.

Preservation Methods

Details procedures for preserving the pump for storage.

Removing Preserving Agent

Explains how to remove preservation agents before operation.

Disposal Procedures

Outlines safe and environmentally compliant disposal methods.

Set-up and Connection

Preparing Set-up

Covers checking ambient conditions and installation site preparation.

Set-up with Foundation

Details the process of placing and fixing the aggregate on a foundation.

Set-up without Foundation

Explains how to set up the unit on a level surface or frame.

Motor Installation

Provides instructions for installing the motor onto the aggregate.

Planning Pipe System

Guides on dimensioning and designing the piping for the pump.

Connecting Pipes

Covers safe and proper connection of suction, pressure, and other pipes.

Fine Adjustment of Coupling

Details the process of aligning the motor and pump coupling.

Electrical Connection

Outlines electrical connection requirements and safety precautions.

Operation

Preparations for Commissioning

Steps required before starting the pump for the first time.

Commissioning Procedures

Instructions for initial start-up and operation.

Switch-off Procedures

Steps for safely shutting down the pump.

Setting the Operating Liquid Flow Rate

Instructions for adjusting the flow rate for cooling.

Decommissioning and Re-commissioning

Procedures for taking the pump out of service and restarting it.

Operating Stand-by Aggregate

Guidance for maintaining standby units.

Maintenance and Servicing

Monitoring and Inspection

Guidelines for regular checks to ensure proper functioning.

Lubrication Intervals for Rolling Bearings

Specifies when and how to lubricate bearings.

Rinsing off Contaminations

Procedures for cleaning the pump from fine-grained contamination.

Preventing Calcification

Advice on avoiding calcification in pump parts.

Disassembly Procedures

Step-by-step instructions for dismantling the pump.

Troubleshooting

Technical Data

Operating Limit Values

Lists critical operating parameters for different pump models.

General Technical Data

Provides key specifications like weight, sound level, and drive power.

Operating Connections

Details port sizes and types for water, suction, and pressure connections.

Mechanical Seal Specifications

Describes the features and types of mechanical seals used.

Ambient Conditions

Specifies permissible temperature and humidity ranges for operation.

Clearances for Heat Dissipation

Lists minimum distances required for adequate cooling.

Tightening Torques

Provides specific torque values for screws, nuts, and fittings.

Permissible Forces and Torques

Defines acceptable forces and torques on pump nozzles.

Adjustment Dimensions

Details impeller gap and position settings for various models.

Lubricants and Preserving Agents

Specifies recommended lubricants and quantities, and preserving agents.

Test Pressure and Accessories

Information on pressure testing and available accessories.

Appendix

Dimension Drawings

Visual representations with dimensions for pump models.

Cross-sectional Drawings

Detailed exploded views of pump components with part numbers.

Conformity Documentation

Includes Certificate of Conformity and EC Declaration of Conformity.

Speck pumpen VH 500 Specifications

General IconGeneral
Voltage230 V
Frequency50 Hz
Impeller MaterialPlastic
Maximum Water Temperature60 °C
TypeCentrifugal pump
Shaft MaterialStainless steel
Protection ClassIP X4
Motor Power500 W
Power500 W