Spectra 1759MG - 1 - Programming Guide
1759MG
System Programming Guide
Software Version 2.0
Default Installer Code
0000 / 000000 (see section [281] on page 18)
Default System Master Code
1234 / 123456 (see section [301] on page 18)
How Do I Enter Programming Mode?
1) Press [ENTER]
.
2) Enter your [INSTALLER CODE].
3) Enter 3-digit [
SECTION] you wish to program.
4) Enter required [
DATA].
Decimal and Hexadecimal Programming Table
Trouble Display
Press the [TBL] or [TRBL] key to view the Trouble Display. Please note that the keypad can be programmed to emit a BEEP
every 5 seconds whenever a new trouble condition has occurred. Press the [
TBL] or [TRBL] key to stop the beeping.
[1]
- No Battery or Low Battery
[8]
- Timer Loss**
[2]
- Wireless Transmitter Low Battery
[9]
- Tamper or Zone Wiring Failure*
[3]
- Power Failure
[10]
- Telephone Line Monitoring Failure
[4]
- Bell Output Disconnected [11]/[STAY] - Fire Loop Trouble*
[5]
- Maximum Bell Current [12]/[BYP] - Module Loss
[6]
- Maximum Auxiliary Current [13]/[MEM] - Wireless Transmitter Supervision Loss*
[7]
- Communicator Report Failure [16]/[FORCE] and [TBL]/[TRBL] flashes - Keypad Fault
* Press the illuminated key ([9], [
STAY] or [MEM]) to view which zones are causing the trouble. Enter the Installer Code to clear
Tamper troubles.
** Press [8] to re-program the time.
Value or Action
What Do I
Press?
What Do I See?
10-Zone LED 16-Zone LED LCD
Values 1 to 9 [1] to [9] [1]
to
[9]
[1]
to
[9] [1]
to
[9]
A (hex only) [0] [0 (10)] [10] 0
B
(hex only)
[STAY] [STAY]
[11] B
C
(hex only)
[BYP] [BYP]
[12] C
D
(hex only)
[MEM] [MEM]
[13] D
E
(hex only)
[TBL] / [TRBL] [TBL]
[14] E
F
(hex only)
[PG] / [FNC1] [PG]
[15] F
Exit Without Saving
[
CLEAR]
[
ENTER] flashes [ARM1] & [STAY1] flash “SECTION [ ]”
Erase Current Digit
[
FORCE]
Displays next digit or next section
Save Data
(hex only)
[ENTER]