1
TABLE OF CONTENTS
Introduction 2
FOR YOUR SAFETY 2
COMPONENTS 2
How to use the Laser System 3
Powering the Laser 3
RC602 Radio Remote Control 3
Turning On/Off the RC602 3
LASER SETUP 4
Turning On/Off the Laser 4
Features and functions 4
Standard Features 5
X-Y-grade entering mode 5
Using the Rotation mode 6
Manual mode 6
Special MENU Features 7
Menu Functions (Radio controlled) 7
Automatic PlaneLok mode 8
Automatic Grade Match 9
Automatic Axis Alignment (only GL622) 10
Activating/Deactivating Standby mode 10
Start Reference Check 10
Setting Menu 10
Info 11
Service menu 11
Special Features - Vertical Setup 12
Line Scan 12
Setting menu details 12
Pairing 12
Pairing the transmitter with remote control 13
Pairing the transmitter with receiver 13
Mask mode 13
Grade Entry 14
Grade Display 14
Sensitivity 14
HI-alert selection 14
User Name 15
Set Password 15
Password On/Off 15
Radio (RF-Channel) 15
Select Language 16
CALIBRATION 16
Checking Calibration of the Y- and X-Axes 16
Checking Calibration of the Z-(vertical) Axis 16
Troubleshooting 17
PROTECTING THE UNIT 18
CLEANING AND MAINTENANCE 18
PROTECTING THE ENVIRONMENT 18
WARRANTY 18
TECHNICAL DATA 19
ELECTROMAGNETICAL COMPATIBILITY 20
GB
130533trimble_GL622_00_Buch 1 29.05.13 07:15

Questions and Answers

  • D
    Destiny MartinezAug 15, 2025
    What to do if the Spectra Measuring Instruments laser beam is blocked?
    • A
      Alexandra SmallAug 15, 2025
      If the laser beam is blocked, ensure there are no obstacles between the transmitter and the HL750.
  • L
    Linda ChristensenAug 18, 2025
    What to do if Spectra Measuring Instruments shows 'Time Out' error?
    • J
      Jerry FloresAug 18, 2025
      If a 'Time Out' error occurs, it means a function could not be completed in the allowed time. Check the radio operating range/connection and ensure a stable laser setup.
  • B
    bhaasAug 22, 2025
    What to do if Spectra Measuring Instruments shows 'No receiver'?
    • C
      Courtney HernandezAug 22, 2025
      If your Spectra Measuring Instruments displays 'No receiver', make sure the receiver is on and paired.
  • L
    Lynn ThompsonAug 25, 2025
    What to do if Spectra Measuring Instruments lost receiver during auto alignment?
    • B
      Brent CisnerosAug 26, 2025
      If the laser loses the receiver after initially finding it, check the operating range for the auto function and restart the auto alignment.
  • K
    kimberly40Aug 28, 2025
    What to do if Spectra Measuring Instruments cannot find the receiver?
    • C
      Christy McculloughAug 28, 2025
      If the laser cannot find the receiver, check the operating range for the auto function and restart the auto alignment.
  • R
    rmeltonSep 1, 2025
    What to do if Spectra Measuring Instruments shows 'HI alert'?
    • L
      Laura BrooksSep 1, 2025
      If you see a 'HI alert' indicating the unit height has changed, check the laser beam elevation after deleting the HI alert.
  • V
    Virginia ReyesSep 4, 2025
    What to do if Spectra Measuring Instruments has Mechanical Limit during Axis Alignment?
    • A
      Ashley GraySep 4, 2025
      If you encounter a mechanical limit during Axis Alignment, Grade Match, or Spot Match, realign the unit closer to the alignment point. Also, check if the existing slope is above +/-25%.
  • S
    Sherri JamesSep 7, 2025
    What to do if Spectra Measuring Instruments has Rake Angle Limit?
    • T
      Terry HowardSep 7, 2025
      If you encounter a Rake Angle Limit, realign the unit closer to the alignment point.
  • M
    Margaret SavageSep 12, 2025
    How to fix temporary EEprom problem on Spectra Measuring Instruments?
    • S
      Sarah HansonSep 12, 2025
      To resolve a temporary EEprom problem, repeat the pairing process and re-enter the customer settings.

Summary

For Your Safety

Laser Safety Precautions

Details warnings about laser radiation, avoiding direct eye exposure, and unauthorized service.

HOW TO USE THE LASER SYSTEM

LASER SETUP

Features and Functions

Standard Features

Special MENU Features

Automatic Operation Modes (PlaneLok, Grade Match, Axis Alignment)

Details on PlaneLok, Grade Match, and Axis Alignment modes for automated laser functions.

Standby, Reference Check, and Settings Menu

Covers activating standby mode, performing reference checks, and accessing the general Setting Menu.

Service

Special Features - Vertical Setup

Setting Menu Functions

CALIBRATION

Checking Y- and X-Axes Calibration

Steps to check horizontal axis calibration accuracy using wall marks over a distance.

Checking Z-(vertical) Axis Calibration

Method to check vertical axis calibration accuracy using a plumb bob.

Troubleshooting

Error Codes and Solutions

Table detailing common error codes, their meanings, and steps to resolve them.

TECHNICAL DATA

Spectra Trimble hl750 Specifications

General IconGeneral
BrandSpectra
ModelTrimble hl750
CategoryMeasuring Instruments
LanguageEnglish