Procedures for installing the instrument according to European regulations.
Guidelines for safe and correct operation of the instrument.
Instructions and warnings related to instrument maintenance.
Physical dimensions and weight of the Cirrus instrument.
Electrical power requirements and specifications for the instrument.
Safety warnings and standards related to the instrument.
Details of external connectors for circuits and accessories.
Description of the front panel layout and status indicators.
Details the external connections and ports on the rear of the instrument.
Specifies the default network IP address configuration for the instrument.
Instructions for modifying the instrument's IP address for network connectivity.
Procedure to restore the instrument's IP address to default settings.
Steps for connecting the instrument to a host PC for operation.
Sequence for powering on the instrument and initial status checks.
Procedure for starting the quadrupole analyzer component for operation.
Instructions for baking the system to reduce background peaks.
Step-by-step procedure for safely shutting down the instrument.
Instructions for safely removing the instrument's outer cover for access.
Overview and identification of internal instrument components.
Procedure for replacing the orifice disk, including tools and steps.
Detailed guide on how to change the instrument's filaments.
Method for cleaning the ion source without removing it from the analyser.
Procedures for cleaning or replacing the entire ion source assembly.
Introduction to the quadrupole analyser and its main functional areas.
Procedure for safely removing the analyser from the vacuum system.
Steps for correctly re-installing the analyser into the vacuum chamber.
Using an ohmmeter for basic analyser diagnostics and continuity checks.
Procedure for checking the status and integrity of the instrument's filaments.
Diagram and description of analyser flange electrical connections.
Exploded diagram of the analyser assembly with open ion-source.
Exploded diagram of the filament plate for open ion-source configuration.
Exploded diagram of the source assembly for open ion-source configuration.
Exploded diagram of the filament plate for PVD ion-source configuration.
Exploded diagram of the source assembly for PVD ion-source configuration.
Details and illustration of the source alignment jig used in maintenance.
Steps to verify the IP address configuration of the host PC for connectivity.
Guide to assigning a static IP address to the host computer for troubleshooting.
Procedure to restore the instrument's IP address to its factory default.
Information and setup for the multi-stream inlet option.
Details on the UDV system, its components, and setup procedures.
Procedure for calibrating the Baratron gauge by checking its zero point.
Basic steps for setting up and configuring the UDV system.
Instructions for baking the UDV valve for optimal performance.