TM
Press CONFIRM key to conrm
and press MENU key to have a
manual regeneration
5. Slowly open the inlet knob on the bypass valve with the bypass tool supplied and allow water to enter
the unit. Allow all air to escape from the unit before turning the bypass fully open. Then allow water
to run to drain for 3-4 minutes or until all media nes are washed out of the softener indicated by
clear water in the drain hose. Open a cold soft water tap nearby and let water run a few minutes or
until the system is free of foreign material resulting from plumbing work. Close the water tap when
water runs clean.
6. Press any button to advance to the BRINE position, when it arrives, press any key to skip the BRINE
cycle. Press any button to advance to the RINSE position.Check the drain line ow. Allow the water to
run for 3-4 minutes or until the water is clear.
7. Press any button to advance to the REFILL position. Check that the valve is lling water into the brine
tank. Allow the valve to rell for the full amount of time as displayed on the screen to insure a proper
brine solution for the next regeneration.
8. The valve will automatically advance to the SERVICE position. Open the outlet knob on the bypass
with the bypass tool supplied. With the bypass open, open the nearest treated water faucet and allow
the water to run until clear.
9. Add salt into the cabinet. Put 40 kgs of crystal water softener salt in the SWS-1.7 cabinet or 15kgs of
crystal water softener salt in the SWS-0.5. The unit will automatically ll the water to the correct level
when it regenerates.
10. Program unit.
If you select DELAY option, the valve will start to regenerate at the
closest day’s REGEN. TIME (default is 02:00)
NOTE
LIQUID BRINE WILL IRRITATE EYES, SKIN AND OPEN WOUNDS -
GENTLY WASH EXPOSED AREA WITH FRESH WATER.
CAUTION
Automatic Raw Water Bypass During Regeneration
The regeneration cycle can last 60 minutes after which softened water service will be restored. During
regeneration, raw water is automatically bypassed. Hot water should be used as little as possible during this
time to prevent raw water from lling the water heater. This is why automatic regeneration is set for a convenient
during the night and manual regenerations should be performed when little or no water will be required.