Model SWS-0.5M SWS-1.7M
Regeneration Type UP Flow
Ingegrated Meter in Bypass Yes
Hardness Removal 480,000mg 1,680,000mg
Media Loaded Yes
Resin Quantity (L) 10 35
Tank Size 10x15 10x44
Salt Storage Capacity (kg) 15 75
Recommended Service Flow Rate (lpm) 6.7 17
Recommended Cycle Settings
Backwash Duration Settings (min) 1 4
Brine Duration Setting (min) 30 110
Rinse Duration Setting (min) 2 7
Refill Duration Setting (min) 3.5 11.3
Salt Used - Per Regeneration (6lb/cf salt dosage) 0.96 kg 3.08 kg
Water Used - Regeneration (L) 48 175
Flow Rate (Only Valve)
Continuous Flow Rate @ 15 psi Pressure Drop (lpm) 78
Peak Flow Rate @ 25 psi Pressure Drop (lpm) 101
Backwash Flow Rate @ 25 psi Pressure Drop (lpm) 30
Pipe Size 3/4" or 1"
Plumbing Connections Includes 3/4" and 1" Straight Fittings
Electrical Requirements
Input 110V-120V/220-240V AC 50/60Hz
Output 12V AC 650mA
Carton Size (mm) 576x434x655 576x434x1,400
Shipping Weight (kg) 21 47
Wat er Su pply Municipal
Water Temperature (oC) 3-38
Water Pressure (bar) 2.06-8.6
3. SPECTRUM Softener
Specications
Performance Data Sheet & Specications
• Capacities of softeners may deviate from the chart above depending on ow rates and raw water
conditions.
• Changing salt settings from factory setting may require changing injector sizes to achieve stated
capacities.
• Hardness removal is based on standard salt setting (96kg/m3).
• Iron content must not exceed 1 ppm. Beyond 1 ppm an iron softener must be used.
• Do not subject the unit to freezing temperatures.
• Do not use water that is microbiologically unsafe without adequate disinfection before or after the
system.
• The manufacturer reserves the right to make product improvements which may deviate from the
specications and descriptions stated herein, without obligation to change previously manufactured
products or to note the change.