2.4GHz Troubleshooting Guide
Problem Possible Cause Solution
The system will
not connect
Your transmitter and
receiver are too close
together
Move transmitter 8 to 12
feet from receiver
You are around metal
objects
Move to an area with less
metal
The model selected is
not the model bound to
Check model selected and
ensure you are bound to
that model
Your transmitter was
accidentally put into bind
mode and is no longer
bound to your receiver
Rebind your transmitter and
receiver
The receiver goes
into failsafe mode
a short distance
away from the
transmitter
Check the receiver
antenna to be sure it is
not cut or damaged
Replace the receiver or
contact Horizon Product
Support
Make sure your receiver
antenna is in an antenna
tube and is above the
vehicle
The receiver quits
responding during
operation
Inadequate battery
voltage
Charge batteries.
Spektrum receivers require
at least 3.5V to operate. An
inadequate power supply
can allow voltage to mo-
mentarily drop below 3.5V
and cause the receiver to
brown out and reconnect
Loose or damaged wires
or connectors between
battery and receiver
Check the wires and
connection between the
battery and receiver. Repair
or replace wires and/or
connectors