Questions and Answers

  • J
    Jennifer LopezAug 10, 2025
    What to do if SPERONI Water Pump connects with very low water intake?
    • S
      Susan BrooksAug 10, 2025
      If your SPERONI Water Pump connects with very low water intake, it could be due to low pressure in the delivery tank's air cushion. Increase the pressure of the air cushion in the filling valve to 1.5 bar.
  • M
    Melissa BarberAug 18, 2025
    What to do if my SPERONI CAM 60/25 will not suck?
    • M
      Michael Greene IIIAug 18, 2025
      If your SPERONI Water Pump isn't sucking water, several issues could be the cause. First, ensure the suction valve is submerged in water, at least 30 cm deep. Next, check that the pump chamber is filled with water; if not, pour water into the suction union. Inspect the suction pipe for any air leaks and ensure it's properly sealed. Also, the suction valve should be airtight, so clean it to ensure a proper seal. Clear any clogs from the suction rose. Finally, verify that the maximum suction height hasn't been exceeded.
  • S
    Sara DelacruzAug 25, 2025
    Why does my SPERONI CAM 60/25 have an insufficient rate of flow?
    • L
      luis77Aug 25, 2025
      An insufficient flow rate in your SPERONI Water Pump can stem from several causes. Check if the suction height is too high. Also, a dirty suction rose can restrict flow, so clean it thoroughly. If the water level is dropping quickly, try setting the suction valve lower down. Foreign bodies might be reducing the pump's flow rate, so clean the pump and replace any worn parts.
  • T
    tfoxAug 31, 2025
    How to troubleshoot a SPERONI CAM 60/25 Water Pump motor that will not start?
    • A
      Anthony Wood MDSep 1, 2025
      If your SPERONI Water Pump motor isn't starting, begin by checking if there's mains voltage present. If there is no voltage, check the voltage. Another possible reason is a jammed pump impeller, so dismantle the pump and clean it. Also, check for a detached thermostat, and if found, dismantle the pump and clean it.

Summary

Pump Operation and Maintenance

1. Safety Measures

General safety instructions for operating the pump.

2. Use

Instructions on the intended use and application of the pressure tank unit.

3. Before Starting

Steps to perform before the initial operation of the pump.

4. Maintenance Instructions

Guidelines for routine maintenance and care of the pressure tank unit.

5. Troubleshooting Table

A guide to identify and resolve common issues with the pump.

SPERONI CAM 60/25 Specifications

General IconGeneral
Pump typeCentrifugal
Power0.37 kW
Voltage230 V
Maximum head25 m
Inlet connection1 inch
Outlet connection1 inch
Head25 m
Frequency50 Hz
Inlet Diameter1 inch
Outlet Diameter1 inch
PhaseSingle