Questions and Answers

  • S
    Samantha HallAug 8, 2025
    What to do if SPERONI CAM 88/22 HL connects with very low water intake?
    • D
      Dennis SmithAug 8, 2025
      If your SPERONI Water Pump connects with very low water intake, it could be due to low pressure in the delivery tank's air cushion. Increase the pressure of the air cushion in the filling valve to 1.5 bar.
  • L
    Laura BellAug 15, 2025
    What to do if my SPERONI CAM 88/22 HL Water Pump will not suck?
    • I
      igarciaAug 15, 2025
      If your SPERONI Water Pump isn't sucking water, several issues could be the cause. First, ensure the suction valve is submerged in water, at least 30 cm deep. Next, check that the pump chamber is filled with water; if not, pour water into the suction union. Inspect the suction pipe for any air leaks and ensure it's properly sealed. Also, the suction valve should be airtight, so clean it to ensure a proper seal. Clear any clogs from the suction rose. Finally, verify that the maximum suction height hasn't been exceeded.
  • C
    Christopher CollinsAug 22, 2025
    Why does my SPERONI CAM 88/22 HL Water Pump have an insufficient rate of flow?
    • G
      gkingAug 22, 2025
      An insufficient flow rate in your SPERONI Water Pump can stem from several causes. Check if the suction height is too high. Also, a dirty suction rose can restrict flow, so clean it thoroughly. If the water level is dropping quickly, try setting the suction valve lower down. Foreign bodies might be reducing the pump's flow rate, so clean the pump and replace any worn parts.
  • C
    Carly Rivera MDAug 30, 2025
    How to troubleshoot a SPERONI CAM 88/22 HL motor that will not start?
    • C
      Christopher HuertaAug 30, 2025
      If your SPERONI Water Pump motor isn't starting, begin by checking if there's mains voltage present. If there is no voltage, check the voltage. Another possible reason is a jammed pump impeller, so dismantle the pump and clean it. Also, check for a detached thermostat, and if found, dismantle the pump and clean it.

Summary

Safety Measures

Use

Operating Instructions

Provides recommendations for initial setup with filters, suction hoses, and foot valves.

Before Starting

Suction Piping

Details correct fitting of suction pipes to prevent air bubbles and ensure proper suction.

Maintenance Instructions

Adjusting connection and cut-off pressure

Explains how to adjust pump pressure settings using the pressure switch.

Troubleshooting Table

SPERONI CAM 88/22 HL Specifications

General IconGeneral
ModelCAM 88/22 HL
CategoryWater Pump
Liquid TypeClean Water
Maximum head22 m
Power0.75 kW
Voltage230/400 V
Max Head22 m
Frequency50 Hz
TypeCentrifugal
Outlet Diameter1 inch
PhaseSingle Phase