Инструкция
по эксплуатации
Насосная станция Speroni CAM 88/22-HL
Цены на товар на сайте:
http://nasosy.vseinstrumenti.ru/poverhnostnye/nasosnye_stancii/marina/cam_8022-hl/
Отзывы и обсуждения товара на сайте:
http://nasosy.vseinstrumenti.ru/poverhnostnye/nasosnye_stancii/marina/cam_8022-hl/#tab-Responses

Questions and Answers

  • A
    ashley57Aug 10, 2025
    What to do if SPERONI CAM 80/22 connects with very low water intake?
    • A
      Alice JohnsonAug 10, 2025
      If your SPERONI Water Pump connects with very low water intake, it could be due to low pressure in the delivery tank's air cushion. Increase the pressure of the air cushion in the filling valve to 1.5 bar.
  • G
    garciakaraAug 17, 2025
    What to do if my SPERONI CAM 80/22 will not suck?
    • H
      Holly SnyderAug 17, 2025
      If your SPERONI Water Pump isn't sucking water, several issues could be the cause. First, ensure the suction valve is submerged in water, at least 30 cm deep. Next, check that the pump chamber is filled with water; if not, pour water into the suction union. Inspect the suction pipe for any air leaks and ensure it's properly sealed. Also, the suction valve should be airtight, so clean it to ensure a proper seal. Clear any clogs from the suction rose. Finally, verify that the maximum suction height hasn't been exceeded.
  • P
    pamelamarshallAug 25, 2025
    Why does my SPERONI CAM 80/22 have an insufficient rate of flow?
    • R
      Richard BestAug 25, 2025
      An insufficient flow rate in your SPERONI Water Pump can stem from several causes. Check if the suction height is too high. Also, a dirty suction rose can restrict flow, so clean it thoroughly. If the water level is dropping quickly, try setting the suction valve lower down. Foreign bodies might be reducing the pump's flow rate, so clean the pump and replace any worn parts.
  • J
    Jessica WatsonAug 31, 2025
    How to troubleshoot a SPERONI CAM 80/22 motor that will not start?
    • S
      stephaniefordAug 31, 2025
      If your SPERONI Water Pump motor isn't starting, begin by checking if there's mains voltage present. If there is no voltage, check the voltage. Another possible reason is a jammed pump impeller, so dismantle the pump and clean it. Also, check for a detached thermostat, and if found, dismantle the pump and clean it.

Summary

Safety Measures

Use

Operating Instructions

General recommendations for operating the pressure tank unit.

Suction Piping

Guidance on fitting the suction pipe for optimal pump performance.

Delivery Piping

Instructions for setting up the delivery piping for proper air expulsion.

Before Starting

Maintenance Instructions

Adjusting connection and cut-off pressure

Allows adjustment of pump's connection and cut-off pressure settings for optimal operation.

Troubleshooting Table

SPERONI CAM 80/22 Specifications

General IconGeneral
Pump typeCentrifugal
Liquid typeClean water
Maximum head22 m
Power0.37 kW
Voltage230 V
Inlet connection1 inch
Outlet connection1 inch
Frequency50 Hz
Inlet Diameter1 inch
Outlet Diameter1 inch
PhaseSingle phase