5.2 Battery Type Default Parameters (parameters set in monitor software)
Parameters cross-reference table for different types of batteries
Voltage to set
Battery type
Over-voltage cut-off
voltage
Floating charging voltage
Low-voltage cut-off return
voltage
Under-voltage warning
voltage
Low-voltage cut-off voltage
Discharging limit voltage
Over-discharge time delay
Equalizing charging
duration
Equalizing charging interval
0 to 250D (0
means the
equalizing
charging function
is disabled)
When selecting User, the battery type is to be self-customized, and in this case, the default
system voltage parameters are consistent with those of the sealed lead-acid battery. When
modifying battery charging and discharging parameters, the following rule must be followed:
Over-voltage cut-off voltage> Charging limit voltage ≥ Equalizing voltage ≥ Boost voltage
≥ Floating charging voltage > Boost return voltage;
Over-voltage cut-off voltage > Over-voltage cut-off return voltage;
Low-voltage cut-off return voltage > Low-voltage cut-off voltage ≥ Discharging limit
More information https://www.caravansplus.com.au