CC335/CC355
SPECIFIC WARNINGS AND CAUTIONS
Do not use a nitrogen cylinder without a pressure regulator. Do not use oxygen in or near a refrigeration
system as an explosion may occur.
The filter-drier may contain liquid refrigerant. Slowly open the fitting nuts and avoid contact with exposed
skin or eyes.
Unless there was a catastrophic failure, such as a blown or ruptured refrigerant hose, additional oil may
not be needed.
Use only the exact oil specified by the compressor manufacturer. Use of oil other than that specified will
void the compressor warrant