SPI 18-010-9 User Manual

SPI 18-010-9
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Zero Setting:
Close the jaws and
ensure that the zero
position is set after
battery installation
by pressing the
[0] button.
Calibration:
It is recommended that this precision measuring
tool be calibrated at a periodic interval as follows:
Annually
At an interval that ensures that the accuracy is
not compromised between calibrations intervals
As outlined in your company's quality manual
Battery Installation:
Button:
A short press of the button will turn on or off
the caliper. Please note that the caliper will
automatically shut off after 5 minutes of non-use.
IN/MM/F Button:
Shortly press the button to switch between Inch,
Metric (mm) and Inch Fraction reading.
Digital Caliper
(Inch/Metric/Fraction)
Operation Manual
0 - 6" 18-010-9
0 - 8" 19-009-0
0 - 12" 19-008-2
© 2016 Swiss Precision Instruments, Inc.
18-010-9 TRI-FOLD ......indd 1 2/7/17 8:21 AM
Question and Answer IconNeed help?

Do you have a question about the SPI 18-010-9 and is the answer not in the manual?

SPI 18-010-9 Specifications

General IconGeneral
BrandSPI
Model18-010-9
CategoryMeasuring Instruments
LanguageEnglish

Summary

Battery Installation

Battery Installation Steps

Instructions on how to install the 3V CR2032 battery correctly.

Basic Operations

Power Button Function

Describes how to turn the caliper on/off and its auto-shutoff feature.

Zero Setting Procedure

How to set the zero position after battery installation using the [0] button.

Unit Selection Button

Explains how to switch between Inch, Metric (mm), and Inch Fraction readings.

Calibration

Calibration Recommendations

Guidance on periodic calibration intervals for maintaining accuracy.

Caliper Components and Specifications

Table A: Caliper Components

Identifies and labels the different parts of the digital caliper.

Caliper Specifications

Details on range, resolution, and accuracy for different caliper models.

Methods of Measurement

External Measurement

Instructions for measuring external (outside) features using the caliper.

Depth Measurement

Procedure for measuring the depth of a feature using the depth bar.

Internal Measurement

Steps for measuring internal (inside) features with the caliper.

Step Measurement

How to measure step features using the beam and slider step faces.

Usage and Care Instructions

Usage Precautions

Advice on avoiding excessive force and proper handling for accurate readings.

Normal Care and Maintenance

Guidance on cleaning measuring surfaces with a dry cloth.