Use and installation manual
Issue date: 28
th
Oct 2009 Revision: IMQ Page : 26/84
Internal switches in the device
A series of switches have been fitted inside the
device, as shown in Fig. 9, which perform the
following functions:
- switch 1:
when set to “MODE ON” this enables the mode
button on the external control panel for
programming the doses required for the drink;
“MODE OFF” disables the mode button on the
external control panel to stop the programming
function.
- switch 2:
when set to “AUTOMATIC WATER FILLING” this
sets the device to refill the water in the tank
automatically; “MANUAL WATER FILLING” sets
to the device to allow the water to be refilled
manually.
- switch 3:
when set to “ON” the front control panel is
operative; “OFF” means the front control panel
is not operative (inhibitor switch to prevent the
operator using the device when the cooling
system is switched on).
- switch 4 (see paragraph 7.7):
when set to “1” = jug option on.
when set to “0” = jug option off.
- button 5:
starts the left-hand product pump
- button 6:
starts the right-hand product pump
The switches accessible by the operator are
switches n° 2,3,4,5,6 (Fig. 9).
The switches accessible by the maintenance
worker are switches n° 1,2,3,4,5,6 (Fig. 9).
Fig. 9