EasyManua.ls Logo

SPM BIG JUICE - Internal Switches

SPM BIG JUICE
84 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Use and installation manual
Issue date: 28
th
Oct 2009 Revision: IMQ Page : 26/84
Internal switches in the device
A series of switches have been fitted inside the
device, as shown in Fig. 9, which perform the
following functions:
- switch 1:
when set to “MODE ON” this enables the mode
button on the external control panel for
programming the doses required for the drink;
“MODE OFF” disables the mode button on the
external control panel to stop the programming
function.
- switch 2:
when set to “AUTOMATIC WATER FILLING” this
sets the device to refill the water in the tank
automatically; “MANUAL WATER FILLING” sets
to the device to allow the water to be refilled
manually.
- switch 3:
when set to ON” the front control panel is
operative; “OFF” means the front control panel
is not operative (inhibitor switch to prevent the
operator using the device when the cooling
system is switched on).
- switch 4 (see paragraph 7.7):
when set to “1” = jug option on.
when set to “0” = jug option off.
- button 5:
starts the left-hand product pump
- button 6:
starts the right-hand product pump
The switches accessible by the operator are
switches n° 2,3,4,5,6 (Fig. 9).
The switches accessible by the maintenance
worker are switches n° 1,2,3,4,5,6 (Fig. 9).
Fig. 9

Table of Contents