Data di emissione: Dicembre, 2018 Revisione: 1 Pag. : 50/80
“FILTER” or “CUT/OUT”
message appears on the
capacitive touch panel
• The filter is dirty and needs to be
cleaned
• The unit is positioned too close to a wall
or other object restricting air flow and
causing the machine to run at a higher
temperature
• The filter is not properly installed
• The unit has been installed near a heat
source, such as a coffee machine, ice
maker or cold beverage machine which
expels hot air from its vents, causing the
machine to run at a high temperature.
• Clean and replace filter following
instructions
• Reposition unit to maximize
ventilation space (see
installation figures)
• Properly install filter see
• Reposition unit to maximize
ventilation space (see
installation figures)
Board error code Possible cause Solution
E14 or E24 or E34 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
• The product consistency is too high
• An ice block is obstructing the auger
rotation
• Reduce the product consistency
• Remove ice blocks
E15 or E25 or E35 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
• An ice block is blocking the auger
rotation
• The gear motor is defective
• Remove ice blocks
• Replace the gear motor
E11 or E21 or E31 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
• The temperature probe of the
corresponding bowl is short circuited.
• Check and replace the probe
E12 or E22 or E32 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
• The temperature probe of the
corresponding bowl is disconnected.
• Check and connect the probe
E01 or E04 or E05 or E06
message appears on the
capacitive touch panel
display.
• The control board is defective • Replace the board
E02 message appears on the
capacitive touch panel
display.
• The condenser temperature probe is
short circuited.
• Check and replace the condenser
probe
E03 message appears on the
capacitive touch panel
display.
• The condenser temperature probe is
disconnected.
• Check and connect the
condenser probe