OPERATION
CHEMICAL COMPATIBILITY:
Be sure the fluids used in the AA(B)10000AUH-03-Z1 are compatible with and will
not cause deterioration of the materials of construction shown in the introduction
to this document.
SAFETY:
To prevent possible ignition, do not disconnect while energized.
Make sure all equipment is rated and approved for the environment in which
it is used.
FLUID SUPPLY:
Make sure maximum pressure rating of 100 psi (7 bar) is not exceeded.
To help prevent clogging problems, the fluid supply line needs to include a
line strainer.
MAINTENANCE
All power to the PulsaJet® nozzle must be turned off before any
maintenance is performed on the unit.
Overspray or other material should not be allowed to build up on the outside
of the PulsaJet nozzle.
If clogging occurs, the valve components can be removed from the front by
first removing the spray tip and then unscrewing the seat. See Rebuild
Instructions below.