5 VL53L1X sensor and algorithm configuration
It is sufficient to set the two FoVs by dividing the 16*16 SPAD array of the VL53L1X sensor into two sub N*16
arrays. For example, N can be chosen within the interval [4, 8]. This means that it is not necessary to use the
same SPADs for front and back ranging. Alternatively, enabling 7*16 SPADs is sufficient to see a person in the
two zones at the same time when this person stands directly under the sensor, in the middle of the two FoVs.
Figure 6. Example of configuration of the SPAD array
UM2600