ADJUSTING THE PRESSURE
4OADJUSTTHEOUTLETAIRPRESSUREUSETHEREDCOLOUREDREGULATORKNOB
and check the pressure on the outlet pressure gauge, Pic. 8.
)FTHEPRESSURENEEDSTOBELOWERTURNANTICLOCKWISE
)FTHEPRESSURENEEDSTOBEHIGHERTURNCLOCKWISE
5SETHEGAUGETOENSUREYOUSETTHECORRECTWORKINGPRESSURE
.OTE$IFFERENTAIRTOOLSREQUIREDIFFERENTOPERATINGPRESSURES!LWAYS
check with the tool manufacturer if unsure.
SAFETY VALVE
Pic. 9
./4%7HENCHECKINGTHESAFETYVALVE!,7!93WEARSAFETYGLASSES
4OCHECKTHEOPERATIONOFTHESAFETYVALVETHEAIRTANKWILLNEEDTOBE
full.
Portable
4IPCOMPRESSORBACKWARDSTHESAFETYVALVEISLOCATEDUNDERTHE
COMPRESSOR'ENTLYPULLTHERINGOUTWARDS4HISSHOULDRELEASEAIR
UNDERPRESSURE2ELEASETHERINGANDWHENTHEPRESSUREHASDROPPED
THEAIRmOWWILLSTOP.OTETHEREWILLSTILLBESOMEAIRLEFTTINTHETANK
Wall Mounted
2EMOVECOMPRESSORFROMTHEWALLMOUNTS0LACEONSTABLEGROUNDOR
TABLE4HENFOLLOWSTEPSABOVEUNDER0/24!",%3ECURELYREMOUNTTHE
COMPRESSORONTHEWALLBEFOREUSING
)FTHESAFETYVALVEDOES./4WORKINTHISMANNER34/0THEAIR
compressor immediately and have the air compressor
CHECKEDSERVICEDBYANAUTHORISEDSERVICECENTRE