iQ Control Box
20 Document # 204144 REV B • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2019, Stanley Access Technologies, LLC.
All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
01.25.2019
Attachment 1
iQ Controls and Indicators
(Sheet 2 of 2)
ITEM CONTROL/INDICATOR DESCRIPTION
1 Motor 2 Connector Motor No. 2 connector.
2 Power Connector Connecon point for incoming line, neutral, and common power wiring.
3 Fuse Controller fuse-- 5 Amp, 250V.
4 Motor 1 Connector Motor No. 1 connector.
5 Terminal Block Connector TB1 Connecon point for 24V power supply and solenoid lock.
6 Terminal Block Connector TB2 Connection point for function switch (rotary or rocker) and Fire
Alarm input.
7 Terminal Block Connector TB6 Push plate outside. Monitored Photo Beam and Test output.
8 Encoder 2 Connector Encoder # 2 Connector.
9 Two Digit Display Displays Controller Status. Also serves as the display for tune-in by
pushbuon switches and indicates encoder movement. High resoluon
encoder may be dim.
10 Encoder 1 Connector Connecon point for motor encoder No. 1.
11 Up Pushbuon Switch Used for manual setup and tuning of door when handheld
is not available.
12 Down Pushbuon Switch Used for manual setup and tuning of door when handheld
is not available.
13 Enter Pushbuon Switch Used for manual setup and tuning of door when handheld is
not available.
14 RS232 RS232 connector. Connecon point for Bluetooth harness.
15 Jumper JP301 Keep jumper installed for Stanguard
TM
installaons. See wiring diagrams
to determine when to remove JP301 for monitored sensor installaons.
16 Terminal Block Connector TB7 Connecon for ECO Pro.
17 Terminal Block Connector TB5 Side screen sensor, door posion switch.
18 Terminal Block Connector TB4 Connecon point for INSIDE / OUTSIDE sensor and push plate.
19 Terminal Block Connector TB3 Connecon point for Stanguard
TM
, safety sensor and breakout switch.
Using jumper wires across TB3 terminals 1 to 5 and 2 to 6,
internal 24 VDC supplies power to mulple external sensors.