iQ Control Box
20      Document # 204144  REV B  •  www.stanleyaccess.com • 1.800.7.ACCESS 
Copyright 2019, Stanley Access Technologies, LLC.
 
All rights reserved. Reproduction 
 
in whole or in part without the express written permission of Stanley is prohibited.
01.25.2019
Attachment 1
iQ Controls and Indicators
(Sheet 2 of 2)
ITEM CONTROL/INDICATOR DESCRIPTION
1  Motor 2 Connector  Motor No. 2 connector. 
2  Power Connector  Connecon point for incoming line, neutral, and common power wiring. 
3  Fuse  Controller fuse-- 5 Amp, 250V. 
4  Motor 1 Connector   Motor No. 1 connector. 
5  Terminal Block Connector TB1  Connecon point for 24V power supply and solenoid lock.
6  Terminal Block Connector TB2  Connection point for function switch (rotary or rocker) and Fire 
Alarm input.   
7  Terminal Block Connector TB6  Push plate outside. Monitored Photo Beam and Test output.
8  Encoder 2 Connector   Encoder # 2 Connector.
9  Two Digit Display  Displays Controller Status. Also serves as the display for tune-in by 
pushbuon switches and indicates encoder movement. High resoluon 
encoder may be dim. 
10  Encoder 1 Connector  Connecon point for motor encoder No. 1. 
11  Up Pushbuon Switch  Used for manual setup and tuning of door when handheld  
is not available. 
12  Down Pushbuon Switch Used for manual setup and tuning of door when handheld  
is not available. 
13  Enter Pushbuon Switch Used for manual setup and tuning of door when handheld is  
not available. 
14  RS232 RS232 connector. Connecon point for Bluetooth harness. 
15  Jumper JP301 Keep jumper installed for Stanguard
TM
 installaons. See wiring diagrams 
to determine when to remove JP301 for monitored sensor installaons. 
16  Terminal Block Connector TB7  Connecon for ECO Pro. 
17  Terminal Block Connector TB5  Side screen sensor, door posion switch.
18  Terminal Block Connector TB4  Connecon point for INSIDE / OUTSIDE sensor and push plate.
19  Terminal Block Connector TB3  Connecon point for Stanguard
TM
, safety sensor and breakout switch.  
Using jumper wires across TB3 terminals 1 to 5 and 2 to 6,  
internal 24 VDC supplies power to mulple external sensors.