Stanley Part Number 204144
REV B 01.2019
Copyright 2019, Stanley Access Technologies, LLC.
Prohibition on Copying: Any unauthorized reproduction, disclosure or distribution of copies by
any person of any portion of this work may be a violation of copyright law of the United States
of America and other countries, could result in the awarding of statutory damages of up to
$250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties.
All rights reserved.
All manuals can be found at
www.stanleymobileapps.com
iQ Controller
Installation and Operation Manual
204144
INCLUDES INSTRUCTIONS FOR
DURA-GLIDE™ 2000/3000, 5200/5300,
DURA-GUARD™, DURA-STORM™, DURACARE™, *5400-SERIES,
*PROCARE™ 8300A, AND DURACARE 7500A TL-FBO
AUTOMATIC SLIDE DOOR SYSTEMS
*Refer to product-specic Installaon Manuals for Wiring Diagrams as they contain the relevant system wiring.

Questions and Answers:

Stanley Dura-Glide 2000 Specifications

General IconGeneral
Operating Voltage24 VDC
Power Input120V AC
Operating SpeedAdjustable, typically 12-18 inches per second
ComplianceUL 325
Motor TypeDC motor
Opening SpeedAdjustable, typically 12-18 inches per second
Closing SpeedAdjustable, typically 12-18 inches per second
Power Supply120V AC, 60Hz
Safety FeaturesObstruction detection

Summary

General Description

Intended Use of iQ Controller

Manual covers installation, wiring, and tune-in for iQ Controller and specific door systems.

Safety and Compliance Precautions

Wiring and Power Instructions

Evaluating Power Requirements

Details requirements for power source, circuit rating, and avoiding interference.

Tune-In Procedures

Tuning via Controller Pushbuttons

Step-by-step guide for tuning the iQ Controller via pushbuttons.

FIS Procedure with Pushbuttons

Final Door Tune-In Adjustments

iQ Controller Controls and Indicators

iQ System Wiring Diagrams

iQ Terminal Block Connections Guide

Compliance Requirements: ANSI/BHMA & UL

ANSI/BHMA A156.10 Compliance

Outlines critical aspects for compliance with ANSI/BHMA A156.10.

UL 325 Entrapment Protection

Specifies criteria for UL 325 entrapment protection, including forces and speeds.

Low Energy Door Compliance (IBC)

Requirements for Low Energy doors per ANSI/BHMA and IBC-2018.

General Troubleshooting Aid

iQ Controller Troubleshooting

Fine Tuning Slide Doors

Door Performance Adjustment Guide

Provides specific adjustments for common door performance issues.