If the door:
HITS THE CLOSE STOP too hard
Set Close Check Length to 50. Set Close Press to 1 and test.
Increase the Close Brake seng unl there is good braking.
Increase or decrease Close Check unl there is smooth moon enter-
ing and in Close Check.
STALLS during opening without any
mechanical reason. . .
Connues to stall and it seems
to happen at the transion
from Open Brake to Open Check
Increase Obstruction Time from .5 seconds to 1.0 seconds
Make small increases to Open Brake.
STALLS during closing without any
obvious reason. . .
Connues to stall and it seems to
happen at the transion to Close
Check
Increase Obstruction Time
Increase Close Check one count at a me
SPEEDS UP during Close Check
Close Check Speed is set too high. Reduce Close Check one count at a
me unl door moon is suitable.
Attachment 7
Fine Tuning Slide Doors
(Sheet 2 of 2)
Tuning the Stanley Automatic Door (Continued).
Match your actual door to one from the list of doors described in the aachment. Start by installing these
sengs. Use the guide below to make adjustments to these sengs.