Stanley Part Number 204144
REV B 01.2019
Copyright 2019, Stanley Access Technologies, LLC.
Prohibition on Copying: Any unauthorized reproduction, disclosure or distribution of copies by
any person of any portion of this work may be a violation of copyright law of the United States
of America and other countries, could result in the awarding of statutory damages of up to
$250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties.
All rights reserved.
All manuals can be found at
www.stanleymobileapps.com
iQ Controller
Installation and Operation Manual
204144
INCLUDES INSTRUCTIONS FOR
DURA-GLIDE™ 2000/3000, 5200/5300,
DURA-GUARD™, DURA-STORM™, DURACARE™, *5400-SERIES,
*PROCARE™ 8300A, AND DURACARE 7500A TL-FBO
AUTOMATIC SLIDE DOOR SYSTEMS
*Refer to product-specic Installaon Manuals for Wiring Diagrams as they contain the relevant system wiring.

Questions and Answers

  • E
    Erik BuckAug 9, 2025
    What to do if Stanley Gate Opener door moves slowly and shows code 33, 34, or 36?
    • M
      Melinda WoodAug 9, 2025
      If your Stanley Gate Opener door moves slowly over several cycles and displays status code 33, 34, or 36, try resetting the power. If the code doesn't clear after resetting the power, call Tech Support.
  • A
    Anthony GreerAug 17, 2025
    Why does my Stanley Gate Opener show status code F2-F3?
    • T
      Teresa BooneAug 17, 2025
      If your Stanley Gate Opener displays status code F2-F3, it indicates a monitored beam failure. To resolve this, verify the wiring and ensure that the 'holding beam type' (index 20) is set appropriately, either to 'Monitored Beam' or 'Non-Monitored Beam'.
  • B
    Brittany TaylorAug 25, 2025
    What to do if Stanley Gate Opener displays status code E4?
    • D
      Deborah RosalesAug 25, 2025
      If your Stanley Gate Opener displays status code E4, verify the sensor wiring and safety logic setting.
  • M
    Michael SmithSep 1, 2025
    What to do if Stanley Gate Opener hits the open stop?
    • C
      cnelsonSep 1, 2025
      To resolve the issue of your Stanley Gate Opener door hitting the open stop or full open bumper, increase the Open Check Length (Index 3).

Summary

General Description

Intended Use

Manual provides installation, wiring, and tune-in instructions for iQ Controller.

Applicability

Manual applies to Dura-Glide series sliding doors and specific models.

Installation Instructions

Installing the iQ Controller

Covers new door installations where the iQ is factory-installed.

Wiring Instructions

Evaluating Power Requirements

Details power source requirements and circuit rating for the iQ Controller.

Connecting Main Power Wiring

Instructions for connecting incoming electrical power to the control box.

Connecting Accessories (As Applicable)

Connects various subsystems like function switch, sensors, and locks to the iQ Controller.

Tune-In Instructions

Tuning In the iQ Controller Using the Controller Pushbuttons

Details how to use pushbuttons for tuning the iQ Controller.

Final Tune-In Adjustments

Final steps for tuning the door, including ANSI/BHMA and UL requirements.

Tuning the Stanley Automatic Door

Guide for making adjustments to door settings to match actual door performance.

Stanley ProCare 8300A Specifications