iQ Control Box
01.25.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204144 REV B 7
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Table 1. FIS Procedure using Pushbuttons
Step Description Display
Index Value Status Code
1 Set Funcon Switch to Closed.
2 Turn power on.
3 Unlock keypad. 99 00 00
4 Restart FIS. 96 01 A0
5 Select door type: Slide, 01 single motor or 02 dual motor. 00 01 (Single)
02 (Dual)
6 Select Handing: 00 Right or 01 Le.
Manually open door and note rotation of belt pulleys.
If counterclockwise (CCW) use right hand during FIS.
If clockwise (CW) use left hand during FIS.
01
00 (Right)
01 (Le)
A0
7 Accept FIS. Display will go to A1. 03 01 A1
8 Make changes: Funcon Switch
01 Rocker or 00 Rotary. The INDEX will start at 00.
11 01 (Rocker)
00 (Rotary)
A1
9 Select Lock Logic: Lock Logic, 00 = Fail Safe; 01 = Fail Secure;
02 = Fail Safe Dura-Max; 03 = Fail Secure Dura-Max.
NOTE: For locks with circuit board, set to 01 Fail Secure.
For locks with no circuit board, set to Fail Safe
or Fail Secure.
07 Lock Logic:
00 = Fail Safe
01 = Fail Secure
02 = Fail Safe
Dura-Max
03 = Fail Secure
Dura-Max
10
Warning: During this sequence the sensors are inactive and the door
has NO SAFETY. To stop the door, TURN POWER OFF or PUT THE DOOR
INTO BREAKOUT.
Function Switch: Switch to OPEN, momentarily, then CLOSED/
LOCKED. The door opens fully, delays and then closes fully.
The iQ displays A2 when FIS is completed.
A2
11 Aer FIS is complete it might be necessary to change index
11 (safety logic) and Index 20 (Safety Beam Type) to match
the systems installed.
Adjust any other index sengs as needed (refer to Table 3
for opons).
12 Lock keypad. 99 01 00
13 Final Tune-In.
Walk test doors to conrm compliance with applicable ANSI
Standards and local codes.