iQ Control Box
18 Document # 204144 REV B • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2019, Stanley Access Technologies, LLC.
All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
01.25.2019
Table 5. Door States
Door State Description
00 Door State is Closed
02 Door State is Opening
04 Door State is in Open Check
06 Door State is Full Open
07 Door State is Closing
09 Door State is in Close Check
10 Open Assist (manual mode door state)
11 Close Assist (manual mode door state)
12 Close Assist (manual mode door state)
14 Door Fault
15 Door State is in Open Stop
16 Door State is in Obstrucon while Closing
17 Door State is in Close Press
19 Lock Release (door state)
NOTE: If the current status code is “Normal operaon—All OK”, the iQ will show the current door state.
Otherwise, the iQ alternates between showing the current status code and the door state.
Final Tune-In Adjustments
1. Refer to ANSI/BHMA A156.10, “Standard for Power Operated Pedestrian Doors,” and aachment 4 and
DETERMINE ANSI and UL door operang requirements.
2. IF Stanguard
TM
threshold sensor is installed, refer to Stanley Access Technologies document No. 203768,
“Stanguard
TM
Threshold Sensor Installaon and Operaon,” and TUNE-IN Stanguard
TM
threshold sensor.
Ensure that the JP301 Jumper is properly installed for StanGuard
TM
Sensors.
3. IF SU-100 moon sensor(s) are installed, refer to Stanley Access Technologies document No. 203957,
“SU-100 Moon Sensor Installaon and Operaon,” and TUNE-IN SU-100 moon sensor(s).
4. IF Optex X Zone T or X Zone ST Sensors are installed, refer to the manufacturers installaon and tune-in instrucons.
5. If Hotron HR100 ST sensors are installed, refer to the manufacturers instrucons.
6. Aer all changes have been made, cycle the door to have the sengs stored in Non-Volale memory.
Then turn power OFF and then back ON to ensure that all of the sengs are permanently stored.
Verify that the correct Safety Logic has been selected for Sensor Monitoring and that the JP301 is in the
correct posion.
DO NOT remove JP301 when Stanguard™ is installed. X Zone T, X Zone ST and HR100 ST monitored sensors
require JP301 to be removed.
7. This step only applies to the Stanley Automac ICU series doors: Refer to ANSI/BHMA A156.38, “American
Naonal Standard for Low Energy Power Operated Sliding and Folding Doors” and Aachment 4 (Page 3 of 3)
and determine ANSI and IBC-2018 door operang requirements.