iQ Control Box
34 Document # 204144 REV B • www.stanleyaccess.com • 1.800.7.ACCESS
Copyright 2019, Stanley Access Technologies, LLC.
All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
01.25.2019
Attachment 4
ANSI/BHMA and IBC Compliance Requirements for
Low Energy Power Operated Sliding Doors
(Sheet 3 of 3)
To ensure that a Low Energy Power Operated Sliding Door operates in accordance with ANSI/BHMA and the
the IBC-2018, the following must be established:
• Acvaon of the door must be by a Knowing Act.
• The Opening Time (speed) of the Door(s) shall be adjusted so that the door(s) open at a speed of 12 inches
per second maximum, from fully closed to fully open.
• When powered open, the door shall remain at the fully open posion for not less than 5 seconds before
starng the closing cycle.
• The Closing Time (speed) of Door(s) shall be adjusted so that the door(s) close at a speed of 6 inches per
second maximum per leaf, from fully open to latch check.
• Latch check shall occur at no less than 2 inches from fully closed.
• The force required to prevent a stopped door from opening or closing shall not exceed 15 lbf (67 N).
• The required Signage must be present.
NOTE: In special applicaons where safety sensors or secondary acvaon sensors are used on
a low energy door, refer to ANSI/BHMA A156.10 for guidance on sensor performance criteria
for the type of sensor selected.