EasyManua.ls Logo

Starmix ISC L-1625 - Display and Control Elements; Fill Level Indicator; Suction Hose Diameter Setting; Motor Speed Adjustment

Starmix ISC L-1625
296 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
en- 23
* depending on model
Read the operating manual carefully before starting to use the vac-
uum cleaner. The operating manual provides important instructions
for safety, commissioning, operation, maintenance and care. Keep
the operating manual in a safe place and, in case you sell the unit,
hand it on to the next owner.
The manufacturer reserves the right to carry out modications to
the design and equipment.
Do not perform any other work than described in this manual.
This machine is intended for commercial use, for example, in
hotels, schools, hospitals, factories, shops, ofces and in the rental
business.
When unpacking, check for completeness and transport damage.
Before use, the operators should be provided with information,
instructions and training for the use of the vacuum cleaner and the
substances that it is to be used for, including the safe procedure for
the removal of the gathered material.
3 Display and control elements
Switch position Function Description
0 Vacuum cleaner is switched off - Plug socket under voltage
I Vacuum cleaner is running
- Plug socket under voltage
- Automatic lter cleaning function off
A
Standby mode for ON/OFF
automatic mode
- Plug socket under voltage
- The vacuum cleaner is switched on and off via the connected electrical/
compressed air tool* at the plug socket
RA
Standby mode for ON/OFF
automatic mode
- Standby mode like >A< plus automatic lter cleaning
Automatic lter cleaning function
- Filter cleaning is performed automatically during the next working break
when the minimum volume ow level is reached (switch setting RA)
Fill level indicator *
- When the container is full and/or there is a blockage in the suction hose, the
full indicator lights up. On the M and H vacuum cleaners, an acoustic signal
is also emitted
35
21
27
Setting the suction hose
diameter *
- On M-/H-/H-asbestos vacuum cleaners for volume ow monitoring, to trigger
an audible warning signal if the air speed falls below 20 m/s
Setting the motor speed* - Adjust the suction power with the speed control

Table of Contents

Related product manuals