Fireaway Inc. Version 1
5852 Baker Road 10/2017
Minnetonka, MN 55345 P/N 19112
3
1. Introduction to the Stat-X Dual Release Control Panel (SDRP)
The SDRP Part No. 830001 provides automatic fire detection and releasing capability for up to
four (4) Stat-X generators without the need for direct power connection. Replaceable internal
lithium batteries supply power to the control panel for up to three (3) years in service, even after
storage. Dual detection and release zones are provided for both automatic and manual
actuation of the fire suppression system, as well as a manual release for both zones
simultaneously. The SDRP is specifically designed for rugged commercial and military on and
off-road vehicle use.
A fully potted, lightweight aluminum enclosure surrounds the military qualified electronic
components. The SDRP provides electrical supervision of fire detection, release, manual
activation as well as battery condition. The SDRP includes a maintenance/transport guarded
toggle switch that can be secured in the "Disarm System" position to disable the system. This
feature is used to extend storage life as well as prevent unwanted discharge during transport or
vehicle maintenance.
A second momentary action guarded toggle switch is provided to perform an on-command
system test of circuit integrity and battery condition. When commanded, the test switch
initiates a built-in test of the fire suppression system and the panel indicates system status
by illuminating either a green System OK LED or a yellow System Trouble LED.
Batteries must be replaced as follows …
- Every three (3) years or ...
- If a system trouble condition persists or …
- Following a system discharge event.