Display:
- The display
shows the selected parameter (A, C, 1-8).
Available parameters:
The heat pump has two temperature sensors that measure the following temperatures:
Parameters
Display range
A current water temperature at inlet -19 °C to +99 °C -
C current temperature at heat exchanger -19 °C to +99 °C -
The heat pump has eight adjustable parameters:
Parameters
Seng range Default
1 desired water temperature 15 °C to 35 °C 27°C
2 Temperature dierence for restart 1 °C to 10 °C 2°C
3 Outlet temperature protecon 30 °C to 80 °C 47°C
4 Automac restart 0 - 1 1
5 Duraon for automac defrost funcon 10 min to 90 min 40min
6 Temperature seng for automac defrost
funcon
-30 °C to 0 °C 0°C
7 Temperature seng for exing automac
defrosng
1 °C to 30 °C 2°C
8 Exit automac defrosng 10 min to 40 min 30min
54