What does error message P4 mean on my Steinbach Heat Pump?
- BBrooke RobertsAug 15, 2025
Error message P4 on your Steinbach Heat Pump indicates that the water flow is too low or the flow sensor is defective. Check the delivery volume of the pump.
What does error message P4 mean on my Steinbach Heat Pump?
Error message P4 on your Steinbach Heat Pump indicates that the water flow is too low or the flow sensor is defective. Check the delivery volume of the pump.
What does error message P1 mean on my Steinbach Heat Pump?
Error message P1 on the display of your Steinbach Heat Pump means that the temperature sensor at the inlet is defective or is not sending a signal.
What does error message P2 mean on my Steinbach BP-39WS-B Mini?
Error message P2 on your Steinbach Heat Pump indicates that the temperature sensor at the outlet is defective or is not sending a signal.
What does error message P3 mean on my Steinbach Heat Pump?
Error message P3 on your Steinbach Heat Pump means the temperature sensor at the heat exchanger is defective or not sending a signal.
What does error message P5 mean on my Steinbach BP-39WS-B Mini?
Error message P5 on your Steinbach Heat Pump indicates that the pressure in the refrigerant circuit is too low.
What to do if liquid is leaking from my Steinbach BP-39WS-B Mini Heat Pump?
If you notice liquid leaking from your Steinbach Heat Pump, it could be due to several reasons: * It may be condensation – check the drain connection and drain line for any clogs. * The water connections might not be tight – inspect the seal and firmly tighten the union nuts. * It could also indicate leaks in the water or refrigerant circuits.
Why Steinbach Heat Pump display does not light up?
If the display of your Steinbach Heat Pump doesn't light up, here are a few potential causes: * The mains plug may not be properly connected to the power socket or extension cable. Disconnect and reconnect it securely. * The RCD adapter might have been triggered. Try pressing the Reset button. If the LED doesn't stay lit, it may indicate an electrical issue. * The power socket or extension cord might not be receiving voltage.
What to do if my Steinbach BP-39WS-B Mini does not start up?
If your Steinbach Heat Pump isn't starting, it could be due to these reasons: * The heat exchanger might not be at operating temperature yet. Wait for 90 seconds after switching it on. * The current water temperature might be at or above the set temperature. Try setting a higher temperature or wait until the current water temperature drops below the set temperature.
Why is there ice forming on the finned heat exchanger of my Steinbach Heat Pump?
Ice forming on the finned heat exchanger of your Steinbach Heat Pump can occur if: * The ambient temperature is too low or the air humidity is too high. In this case, activate the manual defrosting feature.
What to do if water in my swimming pool does not reach the desired temperature with Steinbach BP-39WS-B Mini Heat Pump?
If the water in your pool isn't reaching the desired temperature even when your Steinbach Heat Pump is running, the operating duration of the heat pump may have been too short. Allow 24-48 hours for the water to reach the set temperature.
Instructions for disposing of packaging materials, separating paper and film.
Legal obligation for consumers to dispose of old electrical devices separately.
Proper disposal of refrigerants due to their harmful nature at approved collection points.
Importance of reading and retaining the operating manual for safe use and future reference.
Details on the intended use of the device for private pools and restrictions on commercial use.
Essential safety guidelines and warnings for operating the heat pump to prevent injury or damage.
Verify all parts are present and undamaged, then perform basic cleaning of the device.
Guidance on selecting and preparing a suitable outdoor location for the heat pump installation.
Step-by-step instructions for attaching adapters to the heat pump's water connections.
Description of the heat pump's standby mode and how to switch to operate mode.
Explanation of how the heat pump operates to heat pool water and temperature settings.
Instructions for connecting and testing the RCD adapter for electrical safety.
Steps to activate the heat pump, set desired temperature, and manage parameters.
Steps to disconnect electrical and water supply lines safely.
Instructions for cleaning the heat pump's housing, fan, and heat exchanger.
Checks to perform before every use to ensure the device is in good condition.
Information on identifying and understanding different types of leaks and their causes.
Procedure for preparing the heat pump for winter storage to prevent damage.
Table of problems, their causes, and recommended remedies for the heat pump.
Detailed technical specifications including model, dimensions, power ratings, and performance data.
A comprehensive list of replaceable parts with item numbers and corresponding item codes.
Information on EU conformity and guidelines for responsible product disposal.
Loading...