4. Unscrew the end of the hose from the adapter
on the inlet water connecon
.
When removing the end of the water hose, hold it with the opening facing upwards
to prevent uncontrolled spilling of the remaining water present in the hose.
The water lines have been disconnected.
Cleaning
NOTE!
Improper cleaning can result in damage to the device.
- Clean the surface of the device with clear water aer every use.
-
Do not use any aggressive cleaning agents.
- Do not use any sharp or metallic objects such as knives, hard
puy knives or the like.
- Do not use any cleaning brushes.
- Do not use a high-pressure cleaner.
Cleaning the heat pump
1. Clean the housing and the grille of the fan
with a slightly damp cloth.
2. Clean the ns of the nned heat exchanger
carefully with a vacuum cleaner or
compressed air if necessary.
The ns are extremely sensive and must not be touched!
3. Remove any deposits in the drain connecon
so that condensaon water can
drain unimpeded.
4. Dry o the heat pump with a dry cloth.
The heat pump is now clean.
Inspection
Check the following before every use:
- Is there evidence of damage to the device?
- Is there evidence of damage to the controls?
- Are the accessories in proper condion?
- Are the supply lines and wiring in proper condion?
- Are the venlaon openings free and clean?
Do not put a damaged device or accessory into operaon. Have it inspected and repaired
by the manufacturer, the manufacturer’s customer service or a qualied specialist.
58