The following parameters can be used to customise the sequence of the automac
defrosng feature:
- (5) Duraon of the automac defrosng feature: denes the duraon of the
automac defrosng feature in minutes.
- (6) Temperature seng for the automac defrosng feature: the automac
defrosng feature is started as soon as the “Current temperature on the heat
exchanger” (C) falls below this value in °C.
- (7) Temperature seng for stopping the automac defrosng: the automac
defrosng feature is stopped as soon as the “Current temperature on the heat
exchanger” (C) rises above this value in °C.
- (8) Control mer for stopping the automac defrosng: the automac defrosng
feature is stopped as soon as the duraon set for it in minutes is exceeded.
Do not use any objects for speeding up the defrosng process except those
permied by the manufacturer!
Leaks
If a liquid escapes from the heat pump, it could be one of the following:
- Condensaon water
- Pool water
- Refrigerant
Condensation water
The formaon of condensaon water is normal during operaon and is not a defect. As
the surface of the nned heat exchanger becomes cold, the humidity of the ambient air
condenses and in extreme cases can also solidify to form ice. Condensaon water that
forms collects in the base plate and is drained o through a hole via the drain connecon
. If the drain connecon
is clogged, the condensaon water cannot drain
completely out of the heat pump and substanal quanes can collect there.
Pool water
Escaping pool water indicates that:
• the hose is not connected correctly to the adapter
.
• the adapter
is not screwed onto the heat pump
correctly.
• the seal in the adapter
is defecve or missing.
• the pipe of the circuit inside the heat pump is leaking.
Refrigerant
Escaping refrigerant indicates that the refrigerant circuit in the nned heat exchanger has
a leak. Contact a qualied specialist promptly if you nd a leak in the refrigerant circuit.
60