Display:
-
The display14 shows the selected parameter (A, B, C, 1-8).
Available parameters:
The heat pump has three temperature sensors that measure the following temperatures:
Parameter
Display range
A current water temperature at the inlet -19°C - +99°C -
B current water temperature at the outlet -19°C - +99°C -
C current water temperature at the heat exchanger -19°C - +99°C -
The heat pump features eight adjustable parameters:
Parameter
Setting range Preset
1 desired water temperature 15°C - 35°C 27 °C
2 Temperature difference for restart 1°C - 10°C 2 °C
3 Temperature protection outlet 30°C - 80°C 47 °C
4 Automatic restart 0 - 1 1
5 Duration of automatic defrost function 10 min - 90 min 40 min
6 Temperature setting automatic defrost function -30°C - 0°C 0 °C
7 Temperature setting stop automatic defrost function 1°C - 30°C 2 °C
8 End automatic defrost 10 min - 40 min 30 min
Operation
CAUTION!
Risk of injury!
A damaged device or damaged accessories can lead to injuries.
-
Check the device and the accessories (see the chapter on “Points to
check”).
39