Hints and tips
Every time the cleaner is taken out of the water, the filter cleaner
must be cleaned.
Make sure the pH value of the water is between 7.0 and 7.2.
Make sure the water temperature is between 12°C and 32°C.
After every clean, the drive train must be thoroughly cleaned to en-
sure the same level of grip on the next clean.
After pressing the “Power Off” button, the “Power On” button cannot
be pressed for 30 seconds.
We recommend keeping the cleaner between 5°C and 40°C in a
shaded, well ventilated place. The mains cable should be coiled
around the cable holder for storage. (The floats must not be pushed
along the cable to ensure the cable floats properly in the water.)
Avoid direct sunlight at all times.
We recommend attaching the operating unit with a safety rope, to
avoid any risk of the power pack being pulled into the pool.
Before use, please read the instructions relating to trouble-shooting
thoroughly.
Instructions for mounting the 4 locking plates on the cover
For pools with steps we recommend fitting locking plates to the cov-
er. These locking plates stop the cleaner from tipping.
Attach the stabiliser as shown in the photo. Fig. 22
Screw the screw in through the hole in the cover and tighten. Fig. 23.
Tighten the stabiliser with a Philips screwdriver.
Trouble shooting
Fault
Cause
Solution
The power ca-
ble is twisted
or tangled
Cable was not re-
leased properly
Switch off the unit, re-
lease and uncoil the ca-
ble.
The cable in the wa-
ter is too long.
Remove the excess ca-
ble from the water.
Cleaner is stuck on
the outlet grille
Switch off the filter unit.
The cleaner
cannot reach
all areas.
The power unit is in
the wrong place
Position the power unit
so that the cleaner can
reach all areas properly.
Water circulation in
the pool is switched
on.
Switch off the filter unit.
Connection cable is
too short
Place the greatest possi-
ble length of connecting
cable into the pool, but
bear in mind the corre-
sponding minimum dis-
tance between the oper-
ating unit and the pool
Cleaner does
not climb up
the pool wall
Filter bag is blocked
Replace the filter bag
Algae is growing on
the walls
Clean the pool walls
Water temperature is
too high / too low
Optimal water tempera-
ture is between 10°C and
32°C
Brushes are worn
Contact a dealer, replace
the brushes
The cleaner is too
light, it is tilting
Switch the unit off and al-
low the air to escape
PH value is not cor-
rect
Test the value to keep it
between 7.0 and 7.4
Cleaner is not
operating
Power pack is not ful-
ly plugged in
Check the power cable
and the operating unit.
The cleaner was
Contact a specialist re-
damaged during
transport.
tailer
The operating unit
needs a different
voltage to the local
one.
Contact a specialist re-
tailer
Cleaner does
not sink
There is air in the
cleaner
Switch the unit off, allow
the air to escape, and let
the cleaner sink to the
bottom.
Drive roller
breaks off
Foreign body in the
drive
Contact a specialist re-
tailer
Cleaner comes
up
Cleaner climbs too
high, air in the clean-
er
Switch the unit off, allow
the air to escape.
Cleaner is
faulty
Faulty operation
Contact your retailer
Guarantee
A guarantee will only be undertaken by the manufacturer with regard
to safety and reliability under the following circumstances:
Ø The floor vacuum cleaner is used in accordance with the guid-
ance in the instruction manual.
Ø Only original replacement parts were used in any repairs (Parts
liable to wear and tear are not covered by guarantee).
Consequential damages
We cannot be held liable for damage to the product which is caused
by not following the directions in this manual.
WEEE EU-Regulations
Please consider the regulations in the European Union and help pro-
tect the environment. Bring any faulty electrical parts to a recycling
centre in your town, which recycles electrical equipment in accord-
ance with regulations. Do not dispose of equipment in unsorted
waste bins.
Service
Please do not send the equipment to us without authorisation, but
please contact our service centre initially!
If the equipment has to be collected, it must be packed securely and
the invoice (copy) must the enclosed.
As soon as the unit reaches us, it will be checked for faults by our
claims department, and repaired. On conclusion of this work, your
equipment will be returned to you as quickly as possible.
If this return is not covered by the guarantee, the costs incurred will
be calculated.
Guarantee processing / guarantees are handled by the company
Steinbach VertriebsgmbH.
The item will be repaired by the company Steinbach VertriebsgmbH,
however where no right of return exists it will not be taken back.
Steinbach VertriebsgmbH,
Aistingerstrasse 2, 4311 Schwertberg, Austria
e-mail: service@steinbach.at
www.steinbach.at

Related product manuals