EasyManua.ls Logo

STEINEL sensIQ S User Manual

STEINEL sensIQ S
81 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
sensIQ S
Information
DEGBRFNLIT
ES
PT
SE
DK
FINO
GRTRHUCZSK
PLROSIHR
EE
LT
LVRUBGCN
STEINEL Vertrieb GmbH
Dieselstraße 80-84
33442 Herzebrock-Clarholz
Tel: +49/5245/448-188
www.steinel.de
Contact
www.steinel.de/contact
110059304 10/2018 Technische Änderungen vorbehalten. / Subject to technical modification without notice.
SensIQ S_26spr_Rekonstruktion_SensIQ S 17.10.18 10:03 Seite 1
Question and Answer IconNeed help?

Do you have a question about the STEINEL sensIQ S and is the answer not in the manual?

STEINEL sensIQ S Specifications

General IconGeneral
Sensor typePassive infrared (PIR) sensor
Connectivity technologyWired
Maximum range20 m
Dimensions (WxDxH)74 x 128 x 114 mm
Input voltage100-240 V
Input frequency50/60 Hz
Mounting typeWall
Product colorWhite
Detection angle300 °
Duration adjustment5 - 900 s
Installation height (max)2.5 m
Installation height (min)2 m
International Protection (IP) codeIP54
Operating temperature (T-T)-20 - 50 °C

Summary

Installation and Technical Overview

Principle of Operation

Explains how the sensor detects invisible heat from moving objects for automatic switching.

Safety Warnings for Installation

Crucial safety advice, including ensuring power is off and professional wiring.

Mounting and Wiring Guidance

Instructions for sensor placement, mains supply connection, and wiring examples.

Technical Specifications

Detailed data on dimensions, output, power, coverage, reach, and IP rating.

Unit Functions and Settings

On-Unit Function Controls

Details on adjusting twilight, time delay, and reach directly on the sensor unit.

Film Shrouds for Zone Restriction

Guidance on using film shrouds to limit the detection zone and prevent false triggers.

RC9 Remote Control Operations

Remote Control Settings

Using the remote for light-level, daylight, night mode, and time settings.

Manual Override and Test Modes

Instructions for 4-hour ON/OFF override, installation (test) mode, and reset function.

Troubleshooting and Maintenance

Common Malfunctions and Solutions

Diagnosing and resolving issues like no power, incorrect switching, or false triggers.

Operation, Maintenance, and Disposal

Guidelines for sensor operation, lens cleaning, and environmentally sound disposal.

Manufacturer Warranty and Claims

Information on the 5-year warranty, terms, and procedure for making claims.

Related product manuals