When adjusting in a CCW direction, apply a positive load to the adjuster by
turning an additional
1
/4 turn (8 clicks) CCW, then make the final boresight/zero
adjustment by turning the adjuster CW. For example, to move the adjuster one
(1) click CCW, turn the adjuster CCW 8 clicks and then turn it CW 7 clicks to the
new position.
3.5 FACTORY NEUTRAL PRESET
CAUTION
DO NOT over-adjust the adjusters by forcing them beyond their end of travel.
NOTE
ALWAYS zero the DBAL-I
2
starting with the Adjuster marked U/D.
When moving the adjusters, make sure that the adjustment mechanism has
engaged a detent and has not stopped between detents. Failure to properly
engage a detent may impact accuracy as the laser may move when the
weapon is fired.
The adjuster may offer some resistance as you turn it in a CW direction from
the factory neutral position. When the adjuster is harder to turn, it has
reached the maximum CW travel.
42