3.6.a Boresight Using the Laser Borelight System
WARNING
NEVER boresight in the High Power mode of operation.
CAUTION
DO NOT over-adjust the adjusters by forcing them beyond their end of travel.
NOTE
Always move the adjusters slowly, one click at a time, to prevent the adjuster
from jumping detents.
In extreme cold temperatures the adjusters may offer more resistance.
The adjuster may offer resistance as you turn it in a CW direction from the factory
neutral position. When the adjuster is harder to turn, it has reached the maximum
CW travel.
When the adjuster is at its maximum CW or CCW point of travel and is turned in
the opposite direction, the laser point may trace a small loop on the target. This
is normal and does not indicate a failure condition.
A positive load is required when zeroing the DBAL-I
2
for purposes of retaining the
set alignment. See paragraph 3.4.