71
clean cloth. If a damp cloth is used to clean the battery compartment make
sure to allow the compartment to air dry completely before reinstalling the
battery cap.
5.2.d Battery Cap
Prior to water operations or immersion, inspect the O-ring and the battery cap
to make sure they are free of dirt, moisture or corrosion. Thoroughly clean the
O-rings, battery cap and back of the battery compartment that seals against
the O-ring using Isopropyl Alcohol. After cleaning, or if the O-ring becomes
dried out, lubricate the O-ring using silicone grease. If the O-ring becomes cut
or nicked, it should be replaced.
5.2.e Battery Compartment and Housing Threads
Inspect threading on the battery cap and housing for contamination. If the
threading appears to be oily or dirty, clean with Isopropyl Alcohol using a soft,
clean cloth.
5.2.f Battery Removal and Replacement
Refer to Chapter III, Paragraph 3.2.a for Battery Installation procedures. No
special tools or equipment are required to replace the battery.
5.2.g Replace Remote Cable
See Chapter III, Paragraph 3.2.f to replace the Remote Cable Switch.