36
NOTE:
When using Fine Span Digital Adjust, be sure that the error noticed is
SPAN error. Inaccurate test weights, zero shift, or platform problems may
appear as span error. Correcting for these types of errors with fine span
digital adjust can actually induce larger errors.
To enter a Fine Span digital adjust correction:
Step 1. Enter Quick Calibration mode(see "Quick Calibration") and press the
PRINT key until "SPAN 0.0" is displayed for the scale you wish to modify.
Step 2. Press the SCALE SELECT key until the required adjustment is
displayed.
Step 3. Press PRINT to enter the value. Repeat procedure if necessary.