12
MULTI SCALE OPERATION
COUNTING OPERATION:
Fixed sample operation:
Press the SCALE SELECT key to select the scale you will use to
sample parts.
1) Place the fixed number of sample parts on the scale
platform and press the COUNT key. The display will show
the sample count.
2) Press the SCALE SELECT key to select the desired platform.
3) Place the product to be counted on the scale platform.
The display will show the total piece count.
Press the RESET key and repeat steps one through four to count a different
part.
Variable sample operation:
Press the SCALE SELECT key to select the scale you will use to sample parts.
1) Place the sample parts on the scale platform and enter the
number of samples used via the keyboard.
2) Press the COUNT key. The display will show the sample
count.
3) Place the product to be counted on the scale platform.
The display will show the total piece count.
ENTER TARE WEIGHT:
Entering tare weight of full container:
1) Place a container of parts on the scale platform.
2) Press the SCALE SELECT key to select the desired platform.
3) Enter the weight of the container via the keyboard and
press the TARE key. The weight of the container is
subtracted.
Taring an empty container:
1) Place an empty container on the scale platform
2) Press the SCALE SELECT key to select the desired platform.
3) Press the SHIFT key and the press the TARE key. The
weight of the container is subtracted.
STANDARD FEATURES OPERATION
Counting with a known average piece weight(APW):
1) Place parts on the scale platform.
2) Enter the known average piece weight via the keyboard(use
the decimal key if required).
3) Press the APW key. The display will show the total piece
count.