13
Storing an average piece weight and tare weight in memory:
Note:
either or both can be stored depending on the setup of the
scale.
1) Count parts using the any method.
2) Enter an ID number 1 to 300 via the keyboard.
3) Press the SHIFT key and then the APW|STORE key. The
average piece weight and/or tare
are stored in memory
under the ID number.
Counting parts using stored
average piece weight and/or stored tare weight:
1) Place parts on the scale platform. Use the container if
tare weight stored.
2) Enter the ID number of the part on the keyboard and press
the ID key. The total number of parts will be displayed.
Reviewing a stored average piece weight:
The scale must be in the COUNT mode.
1) Enter the ID number of the part on the keyboard and press
the ID key.
2) Press the APW key. The stored Average Piece Weight will
be displayed.
Reviewing a stored tare value:
1) Enter the ID number of the part on the keyboard and press
the ID key.
2) Press the TARE key. The stored TARE will be displayed.
Clearing an average piece weight, tare, and accumulated quantity from memory:
1) Enter the ID number of the part on the keyboard and press
the ID key.
2) Press the SHIFT key and then the RESET|CLEAR key. The
stored average piece weight, tare, and accumulated
quantity will be cleared from memory.
Reverse Sampling:
The scale must be in the weight mode.
1) Place a full container of parts on the scale.
2) Enter the exact tare weight of the container via the
keypad and press the TARE key.
3) Press the SHIFT/COUNT keys. The display will show decimal
points until motion clears.
4) Remove an adequate number of samples(0.4%) from the
container and enter the number via the keypad.
5) Press the COUNT key. The display will show the total
piece count.
ACCUMULATION OPERATION:
Add to Accumulator: