40
5 - graduation size
10 - graduation size
20 - graduation size
50 - graduation size
unit unit lb Calibration units
Selects the units that were used when the
calibration data was entered(full scale
capacity, graduation size, calibration
weight). The units selected here effect
only calibration
entries.To select
displayed
units see Parameter Setup. The
XC780 can be calibrated with one unit type
and display another. Select:
Lb - Calibration weights are in pounds(lb)
Kg - Calibration weights are in
Kilograms(kg)
gr - Calibration weights are in grams(gr)
1CALib 1CALib F Calibrate 1st scale
Selects either to calibrate scale 1 or
proceed to the next item. Select:
t(rue) - to start calibration of
scale 1.
F(alse) - to not calibrate scale 1 and
proceed to the next item.
The previous four items will be repeated for each scale indicated
by the "SCALES " item.
i.e.
2C 00100
2grd .01
units lb
2CALib t
3C 05000
etc.